Fifty-four consecutive femoral component revisions with uncemented fully porous-coated stems were retrospectively reviewed for the prevalence of intraoperative fracture. Fracture of the femoral diaphysis occurred during insertion of a curved stem in 8 (15%) hips. One additional distal fracture of the femur occurred during exposure of the hip. All fractures occurred with a curved femoral stem. Treatment for intraoperative fractures included open reduction and internal fixation with cortical strut grafts and cables followed by protected weight bearing. This was successful in 6 hips. Even with the use of a curved stem, we report a high prevalence of intraoperative fracture of the femur in revision hip arthroplasty.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.arth.2004.10.013 | DOI Listing |
J Bone Joint Surg Am
January 2025
Institute for Global Orthopaedics and Traumatology, University of California, San Francisco, San Francisco, California.
Background: Although delays in musculoskeletal care in low- and middle-income countries (LMICs) are well documented in the open fracture literature, the impact of surgical delays on closed fractures is not well understood. This study aimed to assess the impact of surgical delay on the risk of infection in closed long-bone fractures treated with intramedullary nailing in LMICs.
Methods: Using the SIGN (Surgical Implant Generation Network) Surgical Database, patients ≥16 years of age who were treated with intramedullary nailing for closed diaphyseal femoral and tibial fractures from January 2018 to December 2021 were identified.
Arch Orthop Trauma Surg
January 2025
Department of Orthopaedics, Wright State University, 30 E Apple St., Suite 2200, Dayton, OH, 45409, USA.
Introduction: We propose and assess the biomechanical stability of medial column screw supplementation in a synthetic distal femur fracture model.
Materials And Methods: Twenty-four low density synthetic femora modeling osteoporotic, intraarticular distal femur fractures with medial metaphyseal comminution were split into two fixation groups: (1) lateral locking distal femur plate (PA- plate alone) and (2) lateral locking distal femur plate with a 6.5 mm fully threaded medial cannulated screw (PWS- plate with screw).
J Bone Joint Surg Am
October 2024
Department of Orthopaedics, Faculty of Medicine, University of British Columbia, Vancouver, British Columbia, Canada.
Background: Fixation of distal femoral fractures remains a challenge, and nonunions are common with standard constructs. Far cortical locking (FCL) constructs have been purported to lead to improved fracture-healing as compared with that achieved with traditional locking bridge plates. We sought to test this hypothesis in a comparative effectiveness clinical trial.
View Article and Find Full Text PDFMetabolites
January 2025
Hypertension Center, People's Hospital of Xinjiang Uygur Autonomous Region, Urumqi 830001, China.
Background: The influence of serum uric acid (SUA) on bone metabolism, as suggested by previous studies, remains a contentious issue. SUA plays a complex role in bone health and hypertension, making it challenging to discern its impact on the skeletal status of middle-aged and elderly hypertensive patients. This study aims to elucidate the effects of SUA on bone health, with a particular focus on its association with osteoporosis and the risk of fractures.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!