Objective: We sought to evaluate the association between first trimester nuchal translucency measurement and the risk for major congenital heart defect in chromosomally normal fetuses.

Study Design: First trimester (10 weeks 4 days of gestation to 13 weeks 6 days of gestation) nuchal translucency was obtained in a large prospective multicenter National Institute of Child Health and Human Development study for Down syndrome prediction. The study, which was conducted between May 1998 and December 2000, was restricted to singleton pregnancies. Gestational age was determined by crown rump length measurements. Perinatal outcomes were determined and included the frequency of major congenital heart defect, which was defined as those cases that potentially could require surgery, intensive medical therapy, or prolonged follow-up time. Logistic regression analysis was used to determine whether nuchal translucency was a significant predictor of congenital heart defect.

Results: There were 8167 chromosomally normal pregnancies, of which 21 cases of major congenital heart defect were identified at follow-up examination (incidence, 2.6/1000 pregnancies). The risk of congenital heart defect rose with increasing nuchal translucency measurements. The mean nuchal translucency value for the normal and congenital heart defect groups were 1.5 mm and 1.9 mm, respectively (P = .05). With a nuchal translucency measurement of < 2.0 mm, the incidence of congenital heart defect was 13 of 6757 pregnancies (1.9 of every 1000 pregnancies). At 2.0 to 2.4 mm, the incidence was 5 of 1032 pregnancies (4.8 of every 1000 pregnancies). At 2.5 to 3.4 mm, the incidence was 2 of 335 pregnancies (6.0 of every 1000 pregnancies). At > or = 3.5 mm, the incidence was 1 of 43 pregnancies (23 of every 1000 pregnancies). Logistic regression analysis confirmed that nuchal translucency was associated significantly with congenital heart defect (odds ratio, 2.1; 95% CI, 1.4-3.1; P = .0004).

Conclusion: Increased first trimester nuchal translucency measurement was associated with a higher risk of major congenital heart defect in chromosomally normal pregnancies. The practical implications of our findings are that patients with unexplained elevations of nuchal translucency may need referral for a fetal echocardiogram.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.ajog.2004.12.086DOI Listing

Publication Analysis

Top Keywords

nuchal translucency
40
congenital heart
40
heart defect
32
major congenital
16
pregnancies 1000
16
1000 pregnancies
16
translucency measurement
12
chromosomally normal
12
pregnancies
12
pregnancies incidence
12

Similar Publications

Background: The literature contains exceedingly limited reports on chromosome 10p15.3 microdeletions. In the present study, two cases of fetuses with pure terminal 10p15.

View Article and Find Full Text PDF

ECEL1 mutation in distal arthrogryposis type 5D: A case report.

Eur J Obstet Gynecol Reprod Biol

December 2024

Department of Neonatology, All India Institute of Medical Sciences, Bhubaneswar, Odisha 751019, India. Electronic address:

Background: Arthrogryposis multiplex congenita involves joint contractures across various body parts. Distal arthrogryposis type 5D (DA5D) is a rare, autosomal recessive subtype affecting distal extremities, with symptoms like knee extension contractures, camptodactyly, overriding fingers, ulnar wrist deviation, and scoliosis.

Case: A 24-year-old pregnant woman with a second-degree relative partner had a fetus showing increased nuchal translucency (3.

View Article and Find Full Text PDF

This retrospective study included 311 patients who had increased nuchal translucency (NT ≥3 mm) or nuchal septations (NSs) during the first trimester from January 2018 to December 2020. These patients were divided into 3 groups: (1) patients with NT thickness between 3 and 5 mm and without NS (NT 3-5 mm group, n = 131), (2) patients with NT thickness >5 mm and without NS (NT >5 mm group, n = 105), and (3) patients with NS (NS group, n = 75). The incidence of abnormal pregnancy outcomes was 92.

View Article and Find Full Text PDF
Article Synopsis
  • - The study investigates the prenatal and postnatal features, along with genetic traits, of Lymphedema-Distichiasis syndrome (LDS) in two Chinese families with FOXC2 gene mutations.
  • - Genetic analysis revealed pathogenic variants in the FOXC2 gene for both families, with literature review yielding a total of 117 identified LDS patients, including prenatal signs in 13 cases and postnatal manifestations in 110.
  • - Key prenatal symptoms of LDS include increased nuchal translucency and fetal edema, while postnatal symptoms commonly feature distichiasis and lymphedema, with only a few cases exhibiting signs before and after birth.
View Article and Find Full Text PDF

Objective:  This study aimed to investigate if retroverted (RV) uterus noted on nuchal translucency (NT) ultrasound is associated with second-trimester pregnancy loss and other adverse pregnancy outcomes.

Study Design:  This was a retrospective cohort study of patients with RV uterus documented on NT ultrasound at a single academic medical center from October 2019 to March 2023. Subjects were identified using a query for "retroverted" uterine position within an obstetric ultrasound imaging program.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!