Modification on the conventional procedure to measure AOC in drinking water.

J Environ Sci (China)

Research Center for Environmental Engineering & Management, Shenzhen Graduate School, Tsinghua University, Shenzhen 518055, China.

Published: July 2005

Additional phosphorus will be introduced to water sample if the conventional procedure is used to measure assimilable organic carbon (AOC) in drinking water. It has been shown that there are the cases that phosphorus is the limiting nutrient for microbial growth in drinking water. The measured value of AOC would not be able to indicate appropriately the regrowth potential of bacteria in this case. The conventional procedure used to measure AOC was modified to avoid the introduction of additional phosphorus to water sample in this study. It was shown that it was feasible to measure AOC in water using the modified procedure. Furthermore, the measured value of AOC determined by the modified procedure could indicate appropriately the regrowth potential of bacteria in drinking water despite either organics or phosphorus was the limiting nutrient for bacterial regrowth.

Download full-text PDF

Source

Publication Analysis

Top Keywords

drinking water
16
conventional procedure
12
procedure measure
12
measure aoc
12
aoc drinking
8
additional phosphorus
8
water sample
8
phosphorus limiting
8
limiting nutrient
8
measured aoc
8