Background: This study was designed to describe a method for measuring root curvature of extracted teeth, compare root curvature of four different dental morphotypes before mechanical instrumentation, and measure root curvature after mechanical instrumentation.
Methods: Fifty-five maxillary (14 central incisors, 13 lateral incisors, 14 cuspids, 14 premolars) extracted teeth were analyzed. Measurements were recorded on the horizontal plane at the most apical point of the cemento-enamel junction (CEJ). A 4 mm wide root portion on the buccal aspect was selected and recorded on this plane. A digital scanner traced the circle coinciding with the profile of this root portion and calculated its radius, arc, chord, and arrow (i.e., the perpendicular bisector of the chord). Since root curvature is the inverse of the radius (1/r), the radius was related to root curvature; the arc to the mesio-distal dimension of the root portion; and the reduction of the arrow to root flattening after mechanical instrumentation. The measurements were recorded four times: before treatment (baseline), after polishing, after a first root planing, and after a second root planing. The radii of each dental morphotype (upper central incisors, upper lateral incisors, upper canines, upper premolars) recorded in the first measurement were calculated and used for the statistical analyses: one-way analysis of variance (ANOVA) test and the Tukey multiple comparison method were used to study the curvature. The measurements of the radius, the arc, and the arrow at the four times were used for the statistical analyses: the two-way ANOVA test and the Tukey multiple comparison method were applied in the study of the root modifications after mechanical instrumentation. The accuracy and reliability of the method were also evaluated.
Results: The mean radii of the four dental morphotypes were: central incisors: 3.613 +/- 0.258 mm; lateral incisors: 2.558 +/- 0.256 mm; canines: 2.822 +/- 0.238 mm; and premolars: 2.321 +/- 0.179 mm. The statistical analyses revealed differences among central incisors, canines, lateral incisors, and premolars. There was no statistically significant difference between lateral incisors and premolars. Regarding the root modifications after mechanical treatment, the radius did not show statistically significant differences in any of the comparisons. The arc and the arrow did not show significant differences between baseline and polishing, while they did show significant differences after the second root planing.
Conclusions: This study indicates that: 1) the method of measuring is accurate and reliable; 2) there are statistically significant differences among the root curvatures of different dental morphotypes; and 3) polishing did not modify the root. A vigorous root planing did not modify root curvature, but it did reduce the mesio-distal dimension and flatten the root surface slightly.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1902/jop.2005.76.5.723 | DOI Listing |
Beijing Da Xue Xue Bao Yi Xue Ban
February 2025
Second Clinical Division, Peking University School and Hospital of Stomatology & National Center for Stomatology & National Clinical Research Center for Oral Diseases & National Engineering Research Center of Oral Biomaterials and Digital Medical Devices, Beijing 100101, China.
Objective: To compare the cyclic fatigue resistance of nickel-titanium files made by 3 new heat treatment in simulated S-shaped root canals at different temperatures.
Methods: Gold heat-treated nickel-titanium files TruNatomy (25 mm, tip size 26#/0.04) and ProTaper Gold (25 mm, tip size 25#/0.
PLoS One
January 2025
Aesthetic and Restorative Dentistry Department, College of Dentistry, University of Baghdad, Baghdad, Iraq.
This study evaluated the extent to which obturation materials bypass fractured endodontic instruments positioned in the middle and apical thirds of severely curved simulated root canals using different obturation techniques. Sixty resin blocks with simulated root canals were used, each with a 50° curvature, a 6.5 mm radius of curvature, and a length of 16.
View Article and Find Full Text PDFLasers Med Sci
January 2025
Department of Endodontics, Faculty of Dentistry, Gülhane Faculty of Dentistry, University of Health Sciences, Ankara, Turkey.
Objective: This study aims to quantitatively compare the effects of standard needle irrigation (SNI), passive ultrasonic irrigation (PUI), EDDY, photon-initiated photoacoustic streaming (PIPS), and shock wave-enhanced emission photoacoustic streaming (SWEEPS) on the apical extrusion of irrigation solutions in teeth with severe canal curvature.
Materials And Methods: Seventy-five teeth with a single root and canal, and curvature angles ranging from 20° to 40°, were selected for this study. Root canal curvatures were measured from buccolingual and mesiodistal radiographs using ImageJ software (version 1.
Clin Case Rep
January 2025
Student Research Committee, School of Dentistry, Mashhad University of Medical Sciences Mashhad Iran.
Radix entomolaris (RE) characterized by an extra root in mandibular molars is a rare phenotype. When this condition coincides with complex root canal curvatures or S-shaped canals, root canal therapy (RCT) challenges arise. The present study presents three cases of RE along with complex root curvatures.
View Article and Find Full Text PDFInt J Dent
January 2025
Department of Endodontics, School of Dentistry, Lorestan University of Medical Sciences, Khorramabad, Iran.
This study compared the apical transportation and centering ratio of ProTaper Next (PTN) and XP-endo Shaper (XPS) nickel titanium (NiTi) rotary files in curved root canals using cone beam computed tomography (CBCT). The current in vitro study involved the mesiobuccal canals of mesial roots in 44 extracted mandibular first molars that exhibited apical curvature ranging from 10° to 30°. Two experimental groups were randomly formed from the teeth ( = 22) and subjected to instrumentation with PTN and XPS.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!