Objective: We developed a new apparatus for long-term heart preservation that combines simple immersion with coronary perfusion. In a previous study, we reported that suppression of pro-inflammatory cytokines, such as tumor necrosis factor alpha (TNF-alpha) and interleukin-1beta (IL-1beta), improved results after transplantation. In this study, we evaluated whether long-term preservation using our apparatus for continuous coronary perfusion, combined with suppression of pro-inflammatory cytokines, improves donor heart function after transplantation in a canine model.

Methods: We used adult mongrel dogs in this study. Coronary vascular beds were washed with University of Wisconsin (UW) solution after arresting hearts with glucose-insulin-potassium solution. The heart was then excised and preserved for 12 hours with a combination of immersion and coronary perfusion using a preservation apparatus. Adult mongrel dogs were divided into 2 groups: the coronary perfusion (CP) group (n = 7) and the FR167653 (FR-CP) group (n = 6). In the CP group, we used a 4 degrees C UW solution for immersion and coronary perfusion. In the FR-CP group, we used a 4 degrees C UW solution supplemented with 20 mg/liter of the anti-inflammatory agent FR167653 for immersion and coronary perfusion. At 2 and at 3 hours after orthotopic transplantation, we compared hemodynamic parameters with pre-operative values in donor animals, with right atrial pressure at 10 mm Hg and with 5 microg/kg/min dopamine infusion. We compared serum concentrations of TNF-alpha from the coronary sinus and compared electron microscopic studies between the 2 groups.

Results: Three hours after transplantation, cardiac output (CO), left ventricular pressure (LVP), and -LVdp/dt were significantly greater (p < 0.05) in the FR-CP group than in the CP group (CO, 178% +/- 65% vs 93% +/- 40%; LVP, 115% +/- 22% vs 73% +/-26%; -LVdp/dt, 168% +/- 13% vs 61% +/- 17%, respectively). Electron microscopic studies showed that glycogen was well preserved in the FR-CP group compared with the CP group. Serum concentrations of TNF-alpha were decreased significantly in the FR-CP group compared with the CP group at 3 hours after reperfusion (161 +/- 54 pg/dl vs 642 +/- 636 pg/dl, respectively).

Conclusion: Hemodynamics after transplantation were significantly better in the FR-CP group than in the CP group. The combined preservation method of continuous perfusion and immersion using our apparatus in conjunction with suppression of pro-inflammatory cytokines improves donor heart function after transplantation.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.healun.2004.01.012DOI Listing

Publication Analysis

Top Keywords

coronary perfusion
24
fr-cp group
24
suppression pro-inflammatory
16
pro-inflammatory cytokines
16
immersion coronary
16
preservation apparatus
12
cytokines improves
12
improves donor
12
donor heart
12
heart function
12

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!