Respiratory motion estimation from slowly rotating x-ray projections: theory and simulation.

Med Phys

Department of Electrical Engineering and Computer Science, University of Michigan, Ann Arbor, Michigan 48109-2122, USA.

Published: April 2005

Understanding the movement of tumors caused by respiratory motion is very important for conformal radiatherapy. However, respiratory motion is very difficult to study by conventional x-ray CT imaging since object motion causes inconsistent projection views, leading to artifacts in reconstructed images. We propose to estimate the parameters of a nonrigid, free breathing motion model from a set of projection views of the thorax that are acquired using a slowly rotating cone-beam CT scanner. This approach involves deforming a motion-free reference thorax volume according to the estimated parameters and comparing its projections to the corresponding measured projection views. The parameters are optimized by minimizing a regularized squared error cost function. Simulation results with a fan-beam geometry show good agreement between the estimated motion and the true motion, which supports the potential of this approach for estimating four-dimensional (three-dimensional spatial + temporal) respiratory motion.

Download full-text PDF

Source
http://dx.doi.org/10.1118/1.1879132DOI Listing

Publication Analysis

Top Keywords

respiratory motion
16
projection views
12
slowly rotating
8
motion
7
respiratory
4
motion estimation
4
estimation slowly
4
rotating x-ray
4
x-ray projections
4
projections theory
4

Similar Publications

Background: In order to develop contemporary telehealth curricula for entry-to-practice physiotherapy programs that develop the capabilities required to practice telehealth, it is important to evaluate the delivery of telehealth practices within the physiotherapy profession.

Objective: To assess the current literature to (i) determine what types of assessments and interventions have been delivered via synchronous forms of telehealth (videoconferencing and telephone) by physiotherapists (ii) determine which platforms were used for service delivery and which practice areas have delivered synchronous telehealth physiotherapy assessments and interventions.

Design: Scoping review adhering to Joanna Briggs Institute guidelines.

View Article and Find Full Text PDF

This study was conducted to evaluate the use of 4-dimensional (4D) maximum intensity projection (4D-MIP) to compensate for the disadvantages of average intensity projection (AIP), which is used to determine the internal target volume (ITV) in lung tumors. A respiratory motion phantom with a simulated tumor was imaged using 4D computed tomography (4D-CT). AIP and 4D-MIP were generated based on 10 phases of 4D-CT, followed by contouring of the ITV and ITV; these were compared with the ITV contoured in 10 phases of 4D-CT (ITV).

View Article and Find Full Text PDF

Continuous respiration monitoring is an important tool in assessing the patient's health and diagnosing pulmonary, cardiovascular, and sleep-related breathing disorders. Various techniques and devices, both contact and contactless, can be used to monitor respiration. Each of these techniques can provide different types of information with varying accuracy.

View Article and Find Full Text PDF

Multispectral transmission imaging has emerged as a promising technique for imaging breast tissue with high resolution. However, the method encounters challenges such as low grayscale, noisy transmission images with weak signals, primarily due to the strong absorption and scattering of light in breast tissue. A common approach to improve the signal-to-noise ratio (SNR) and overall image quality is frame accumulation.

View Article and Find Full Text PDF

Whole-body PET imaging is often hindered by respiratory motion during acquisition, causing significant degradation in the quality of reconstructed activity images. An additional challenge in PET/CT imaging arises from the respiratory phase mismatch between CT-based attenuation correction and PET acquisition, leading to attenuation artifacts. To address these issues, we propose two new, purely data-driven methods for the joint estimation of activity, attenuation, and motion in respiratory self-gated TOF PET.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!