Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Purpose: The best way to apply the pretension force to the soft tissue graft during anterior cruciate ligament (ACL) reconstruction remains controversial. We compared manual, intra-, and extra-articular pretension techniques and determined the magnitude of displacement of the femur-graft-tibia complex in response to repetitive loading.
Type Of Study: A biomechanical-controlled study.
Methods: Fresh porcine knees and profundus digital flexor tendons of hind limbs were used. Specimens were divided into 3 groups. Group A (manual pretension, n = 9) consisted of grafts that were pretensioned only by a maximal manual pull before final fixation on the tibial side. Group B (extra-articular pretension, n = 9) consisted of grafts that were pretensioned using a commercial tensiometer at 89 N for 15 minutes on the tendon preparation board, followed by pulling using maximal manual force before final fixation. Group C (intra-articular pretension, n = 9) consisted of grafts that were fastened on the femoral side first and then underwent application of a pretension force at 89 N for 5 minutes before final fixation on the tibial side. These femur-graft-tibia complexes from the 3 groups were loaded from 0 to 150 N at a frequency of 1 Hz for 1,000 cycles and then underwent a tensile load-to-failure test at a rate of 150 mm/min.
Results: The displacement of the femur-graft-tibial complex in response to cyclic loading for group C (5.4 +/- 0.3 mm) was significantly lower than those for groups A (12.5 +/- 1.1 mm) and B (8.8 +/- 0.8 mm) (P < .001). The fixation stiffness of group C (47.9 +/- 17.6 N/mm) was significantly greater than that of group A (32.5 +/- 9.7 N/mm) (P < .05) but not significantly different from that of group B (53.1 +/- 9.1 N/mm). The ultimate failure load in each group was not significantly different.
Conclusion: Intra-articular pretension of the graft before final fixation can significantly minimize graft elongation at time 0 compared with manual and extra-articular pretension.
Clinical Relevance: Intra-articular or in vivo pretension of the graft using instruments may minimize the graft elongation in the early period of rehabilitation after ACL reconstruction.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.arthro.2005.01.013 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!