A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

The effect of three different calcium phosphate implant coatings on bone deposition and coating resorption: a long-term histological study in sheep. | LitMetric

The present study investigated the hypothesis that hydroxyapatite (HA), tricalcium phosphate (TCP), and a HA-gel coated on endosseous titanium (Ti) implants by spark discharging (SD) and dip coating would achieve predictable osseointegration without evident bioresorption of the coatings on the long term. A costal sheep model was used for the implantation of the HA/SD, HA/TCP/SD, and HA-gel/SD specimens, which were retrieved 6 and 12 months following implantation. HA and Ti coatings on implants obtained by conventional plasma spraying (HA/PS, Ti/PS) were used as controls. Microscopy showed that osseointegration was achieved from all types of implants. No evidence for bioresorption of the HA/SD, HA/TCP/SD, and HA-gel/SD coatings was present but cohesive failure with disruption of the coating/implant interface was seen. A statistical analysis of the histomorphometrical data showed no time-dependent effect, however. HA/PS coatings achieved significantly higher bone-implant contact (BIC) percentages of the total implant surface (toBIC) than the other types of coatings (P=0.01). If the BIC percentages were traced separately for implant portions placed into cortical and cancellous bone (coBIC and caBIC, respectively), detailed analysis showed that the caBIC values of HA-gel/SD and HA/PS coatings were significantly higher than that of the other types of coatings (P=0.01). CaBIC values were highly correlated with toBIC values (P<0.001). The present study showed that the preparation techniques used produced thin, dense, and unresorbable coatings that achieved osseointegration. Compared with the control coatings, however, only HA-gel/SD coating can be recommended from the investigated preparation techniques for a future clinical use if a better coating cohesion is achieved.

Download full-text PDF

Source
http://dx.doi.org/10.1111/j.1600-0501.2004.01080.xDOI Listing

Publication Analysis

Top Keywords

coatings
8
ha/sd ha/tcp/sd
8
ha/tcp/sd ha-gel/sd
8
ha/ps coatings
8
bic percentages
8
types coatings
8
coatings p=001
8
cabic values
8
three calcium
4
calcium phosphate
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!