Reconstitution of trabecular meshwork GAGs: influence of hyaluronic acid and chondroitin sulfate on flow rates.

J Glaucoma

Laboratory for Oculo-Cerebrospinal Investigation, Division of Neurosurgery, Children's Memorial Medical Center and Department of Ophthalmology, Northwestern University Medical School, Chicago, IL, USA.

Published: June 2005

Purpose: This study was undertaken to determine whether the concentration of hyaluronic acid (HA) and of chondroitin sulfate (CS) occurring in the normal and the primary open-angle glaucoma (POAG) trabecular meshwork (TM) influences flow rates in vitro as a function of pressure.

Methods: We tested 100, 500, and 4000 kDa molecular weight HA, CS, reconstituted normal and POAG TM HA-CS and juxtacanalicular connective tissue (JCT) HA-CS in a micro test chamber to determine initial and steady-state flow rates. The resistance and permeability (Ko) were calculated; Linear Newtonian mechanics were used to determine the possible contributions of the hydrophobic interactions of HA.

Results: Initial flow rates increased in the pressure range of 5 to 20 mm Hg for the three HA preparations and the flow rates declined in the pressure range of 20 to 40 mm Hg. Flow rates of reconstituted normal TM and JCT were optimum at 10 mm Hg and then declined with increasing pressure. Flow rates of reconstituted POAG TM and JCT were optimum only at 5 mm Hg and then declined. The steady-state rate of POAG JCT HA-CS at 10 mm Hg was slow: the transition time (ie, the time required to start an increase in flow rate) was 29 hours and the lag time (ie, the time required to obtain steady-state flow rate) was 17 hours. The maximum flow rate in POAG JCT HA-CS decreased by 37.2% from the normal JCT HA-CS. The calculated resistance of reconstituted POAG JCT HA-CS was approximately 18% of the total resistance of the human JCT compared with 10% in the normal JCT.

Conclusions: Hyaluronic acid and CS contribute to flow resistance and influence flow rate in vitro. The influence of HA is particularly sensitive to an increase in the pressure gradient, which may be caused by unfolding of the hydrophobic interactions of HA polymers that further entangles the HA polymer. The POAG JCT HA-CS concentrations represent a significant factor in outflow resistance in POAG, particularly at higher pressures.

Download full-text PDF

Source
http://dx.doi.org/10.1097/01.ijg.0000159130.00710.78DOI Listing

Publication Analysis

Top Keywords

flow rates
28
jct ha-cs
24
poag jct
20
flow rate
16
hyaluronic acid
12
flow
12
jct
9
trabecular meshwork
8
acid chondroitin
8
chondroitin sulfate
8

Similar Publications

Blood Flow Restricted Resistance Exercise in Well-Trained Men: Salivary Biomarker Responses and Oxygen Saturation Kinetics.

J Strength Cond Res

December 2024

Jayhawk Athletic Performance Laboratory, Wu Tsai Human Performance Alliance, University of Kansas, Lawrence, Kansas.

Eserhaut, DA, DeLeo, JM, and Fry, AC. Blood flow restricted resistance exercise in well-trained men: Salivary biomarker responses and oxygen saturation kinetics. J Strength Cond Res 38(12): e716-e726, 2024-Resistance exercise with continuous lower-limb blood flow restriction (BFR) may provide supplementary benefit to highly resistance-trained men.

View Article and Find Full Text PDF

Quantitative Measurement of Molecular Permeability to a Synthetic Bacterial Microcompartment Shell System.

ACS Synth Biol

January 2025

Environmental Genomics and Systems Biology Division, Lawrence Berkeley National Laboratory, Berkeley, California 94702, United States.

Naturally evolved and synthetically designed forms of compartmentalization benefit encapsulated function by increasing local concentrations of substrates and protecting cargo from destabilizing environments and inhibitors. Crucial to understanding the fundamental principles of compartmentalization are experimental systems enabling the measurement of the permeability rates of small molecules. Here, we report the experimental measurement of the small-molecule permeability of a 40 nm icosahedral bacterial microcompartment shell.

View Article and Find Full Text PDF

Slip flow, a fluid flow enhanced in comparison to that calculated using continuum equations, has been reported for many nanopores, mostly those with hydrophobic surfaces. We investigated the flow of water, hexane, and methanol through hydrophilic nanopores in silica colloidal crystals. Three silica sphere sizes were used to prepare the crystals: 150 ± 30, 500 ± 40, and 1500 ± 100 nm.

View Article and Find Full Text PDF

Background: Polysomnography (PSG) is resource-intensive but remains the gold standard for diagnosing Obstructive Sleep Apnea (OSA). We aimed to develop a screening tool to better allocate resources by identifying individuals at higher risk for OSA, overcoming limitations of current tools that may under-diagnose based on self-reported symptoms.

Methods: A total of 884 patients (490 diagnosed with OSA) were included, which was divided into the training, validation, and test sets.

View Article and Find Full Text PDF

Aluminum Induces Neurotoxicity through the MicroRNA-98-5p/Insulin-like Growth Factor 2 Axis.

ACS Chem Neurosci

January 2025

Department of Occupational Health, School of Public Health, Shanxi Medical University, Taiyuan, Shanxi 030001, China.

Aluminum is a well-known and widely distributed environmental neurotoxin. This study aimed to investigate the effect of miR-98-5p targeting insulin-like growth factor 2 (IGF2) on aluminum neurotoxicity. Thirty-two Sprague-Dawley rats were randomly divided into four groups and administered 0, 10, 20, and 40 μmol/kg maltol aluminum [Al(mal)], respectively.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!