Bone loss may affect the structure of cancellous bone. But its effect on trabeculae with different characteristics, like rods and plates, is not accurately known. This study analyzes the effect of bone loss on individual rod-like and plate-like trabeculae. 94 specimens were obtained from mandibular condyles from both dentate and edentate humans and scanned with a micro-CT scanner. The bone volume fraction (BV/TV) of these specimens ranged from 7% to 30%. Next, the rod-like and plate-like trabeculae were identified with an especially developed algorithm. Plate volume fraction (PV/TV), rod volume fraction (RV/TV), plate thickness, rod thickness, number of plates, and number of rods were determined. In individual specimens, the thickness of the rods ranged from 40 mum to 180 mum, while the thickness of the plates ranged from 40 mum to 300 mum. In every specimen, the thickness of the plates was larger than the thickness of the rods. Statistical analysis revealed that PV/TV was proportional (r = 0.98, P < 0.001) and RV/TV inversely proportional (r = -0.45, P < 0.001) to BV/TV. Also the thickness of the plates correlated with BV/TV (r = 0.62, P < 0.001), while the thickness of the rods (mean = 90 mum, SD = 7 mum) remained constant (r = -0.09, P = 0.378). A four-fold reduction of the bone volume fraction was accompanied by a three-fold reduction of the number of plates and a 40% reduction of their thickness, but also by a three-fold increase in the number of rods and RV/TV. It was concluded that the effect of bone loss on plate-like trabeculae was opposite to its effect on rod-like trabeculae. Remarkably, the thickness of the rods (90 mum) was independent of the bone volume fraction. This suggests that there is a minimal thickness for trabeculae.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.bone.2005.02.018 | DOI Listing |
Circ Heart Fail
January 2025
Bruce Rapport Faculty of Medicine, Technion-Israel Institute of Technology, Haifa, Israel (I.R.H., N.K., C.B., O.C.).
Background: The therapeutic armamentarium for heart failure with preserved ejection fraction (HFpEF) remains notably constrained. A factor contributing to this problem could be the scarcity of in vitro models for HFpEF, which hinders progress in developing new therapeutic strategies. Here, we aimed at developing a novel, comorbidity-inspired, human, in vitro model for HFpEF.
View Article and Find Full Text PDFSoft Matter
January 2025
Leibniz-Institut für Polymerforschung Dresden e.V., Hohe Strasse 6, Dresden, 01069, Germany.
Field-induced microstructure evolution can play an important role in defining the coupled magneto-mechanical response of Magneto-Active Elastomers (MAEs). The behavior of these materials is classically modeled using mechanical, magnetic and coupled magneto-mechanical contributions to their free energy function. If the MAE sample is fully clamped so it cannot deform, the mechanical coupling is reduced to the internal microscopic deformations caused by the particles moving and deforming the elastic medium that surrounds them.
View Article and Find Full Text PDFClin Cardiol
January 2025
Research Laboratory, Molecular Bases of Human Pathology, LR19ES13, Faculty of Medicine, University of Sfax, Sfax, Tunisia.
Background: Endothelial function (EndFx) is a core component of cardiovascular (CV) health and cardioprotection following acute myocardial infarction (AMI) treated with primary percutaneous coronary intervention (PCI).
Hypothesis: AMI patients experience endothelial dysfunction (EndDys), associated with traditional CV risk factors and sleep patterns. EndFx may also predict short and mid-term outcomes.
Eur J Heart Fail
January 2025
Medical University of South Carolina, Charleston, SC, USA.
Aims: Early identification and management of worsening heart failure (HF) is necessary to prevent disease progression and hospitalizations. The ALLEVIATE-HF (Algorithm Using LINQ Sensors for Evaluation and Treatment of Heart Failure) trial is a prospective, randomized, controlled, double-blind, multicentre trial that aims to assess the safety and efficacy of using the Reveal LINQ™ insertable cardiac monitor (ICM) in patients with HF to continuously monitor and evaluate HF risk status and guide timely interventions.
Methods: The ICM algorithm uses parameters derived from electrocardiogram (atrial fibrillation [AF], ventricular rate during AF, heart rate variability, and night heart rate), three-axis accelerometer (patient activity duration), and subcutaneous bioimpedance (fluid volume, respiration rate).
Rev Port Cardiol
January 2025
Cardiology Department, Hospital Santa Cruz, Centro Hospitalar Lisboa Ocidental, Lisbon, Portugal.
Introduction And Objectives: Pulmonary vein (PV) isolation is one of the cornerstones of rhythm-control therapy for symptomatic atrial fibrillation (AF) patients. Pulsed field ablation (PFA) is a novel ablation modality that involves the application of electrical pulses causing cellular death, and it has preferential tissue specificity. In this study, we aimed to share a one-year single center experience of AF ablation with PFA.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!