A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Can the urine dipstick test reduce the need for microscopy for assessment of systemic lupus erythematosus disease activity? | LitMetric

Objective: Urine microscopic examination is an important component of the Systemic Lupus Erythematosus Disease Activity Index (SLEDAI). We investigated whether the urine dipstick test can reduce the need for microscopy for the assessment of SLEDAI.

Methods: We studied 269 urine samples from 259 SLE patients with Albustix and Hemastix reagent strips. The results were compared to concomitant microscopic examination of urinary sediment.

Results: When trace red blood cell was defined as the cutoff, the sensitivity, specificity, and negative predictive value (NPV) of the Hemastix urine test were 0.98, 0.53, and 0.99, respectively, for hematuria; 0.82, 0.47, and 0.90, respectively, for the presence of pyuria; and 0.91, 0.44, and 0.98, respectively, for the presence of casts by microscopic examination. When proteinuria of 1+ was defined as the cutoff, the sensitivity, specificity, and NPV of the Albustix test were 1.00, 0.46, and 0.99, respectively, for urinary casts; and 0.82, 0.49, and 0.90, respectively, for the presence of pyuria. When both Albustix and Hemastix were applied as screening test, urine microscopy could be reduced by 27%; however, 8% of cases with normal Albustix and Hemastix tests had at least one abnormality on urine microscopy examination.

Conclusion: In patients with SLE, a combination of Albustix and Hemastix urine tests showed reasonable sensitivity to detect abnormalities in urine sediment. Based on these results, routine urine microscopy can be limited to SLE patients with abnormal Albustix or Hemastix tests. Rarer causes of abnormal renal function in lupus, such as tubulointerstitial nephritis or drug induced interstitial nephritis, would be manifested by pyuria and therefore would not necessarily be detected by changes in the blood and protein detectors on the urine dipstick.

Download full-text PDF

Source

Publication Analysis

Top Keywords

albustix hemastix
20
urine dipstick
12
microscopic examination
12
urine microscopy
12
urine
11
dipstick test
8
test reduce
8
reduce microscopy
8
microscopy assessment
8
systemic lupus
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!