Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Objective: Urine microscopic examination is an important component of the Systemic Lupus Erythematosus Disease Activity Index (SLEDAI). We investigated whether the urine dipstick test can reduce the need for microscopy for the assessment of SLEDAI.
Methods: We studied 269 urine samples from 259 SLE patients with Albustix and Hemastix reagent strips. The results were compared to concomitant microscopic examination of urinary sediment.
Results: When trace red blood cell was defined as the cutoff, the sensitivity, specificity, and negative predictive value (NPV) of the Hemastix urine test were 0.98, 0.53, and 0.99, respectively, for hematuria; 0.82, 0.47, and 0.90, respectively, for the presence of pyuria; and 0.91, 0.44, and 0.98, respectively, for the presence of casts by microscopic examination. When proteinuria of 1+ was defined as the cutoff, the sensitivity, specificity, and NPV of the Albustix test were 1.00, 0.46, and 0.99, respectively, for urinary casts; and 0.82, 0.49, and 0.90, respectively, for the presence of pyuria. When both Albustix and Hemastix were applied as screening test, urine microscopy could be reduced by 27%; however, 8% of cases with normal Albustix and Hemastix tests had at least one abnormality on urine microscopy examination.
Conclusion: In patients with SLE, a combination of Albustix and Hemastix urine tests showed reasonable sensitivity to detect abnormalities in urine sediment. Based on these results, routine urine microscopy can be limited to SLE patients with abnormal Albustix or Hemastix tests. Rarer causes of abnormal renal function in lupus, such as tubulointerstitial nephritis or drug induced interstitial nephritis, would be manifested by pyuria and therefore would not necessarily be detected by changes in the blood and protein detectors on the urine dipstick.
Download full-text PDF |
Source |
---|
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!