A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Reproducible assessment of radiolucent lines in total knee arthroplasty. | LitMetric

The Knee Society Total Knee Arthroplasty Radiographic Evaluation and Scoring System was introduced to encourage uniform reporting of radiographic outcome. However, the method for evaluation of radiolucent lines has been shown to be unreliable. Because it has been shown that reducing the complexity of classification systems increases reliability and reproducibility, we questioned whether a simplification of the Radiographic Evaluation and Scoring System would improve reliability and reproducibility. A new system for assessment of radiolucent lines was introduced, and the interobserver reliability and intraobserver reproducibility were studied in 100 patients with 120 total knee replacements. For the new system the mean kappa intraobserver reproducibility coefficient was 0.71 (range, 0.62-0.85) for the femoral component, 0.86 (range, 0.80-0.96) for the tibial component, and 0.58 (range, 0.46-0.75) for the patella prosthesis. The mean interobserver reliability coefficient among three observers was 0.61 (range, 0.45-0.72) for the femoral component, 0.82 (range, 0.73-0.88) for the tibial component, and 0.58 (range, 0.43-0.72) for the patella prosthesis. The new system for assessment of radiolucent lines increased reliability and reproducibility and should supplement the Knee Society's Radiographic Evaluation and Scoring System.

Download full-text PDF

Source
http://dx.doi.org/10.1097/01.blo.0000153077.79573.a4DOI Listing

Publication Analysis

Top Keywords

radiolucent lines
16
assessment radiolucent
12
total knee
12
radiographic evaluation
12
evaluation scoring
12
scoring system
12
reliability reproducibility
12
knee arthroplasty
8
system assessment
8
interobserver reliability
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!