Glycosides, having spacers functionalized with an aldehyde or a carboxylic group, were immobilized through reductive amination or amidation, respectively, onto amino-functionalized glass slides. Hybridization experiments with lectins exhibited very little nonspecific protein binding, hence precluding the necessity for the blocking of unreacted functional groups on the glass slide. The covalency and the concentration dependency of the sugar ligation to the glass slide were demonstrated; the reversibility and the selectivity of lectin-carbohydrate interactions were shown.

Download full-text PDF

Source
http://dx.doi.org/10.1002/cbic.200400300DOI Listing

Publication Analysis

Top Keywords

glass slides
8
glass slide
8
methods generation
4
generation carbohydrate
4
carbohydrate arrays
4
glass
4
arrays glass
4
slides evaluation
4
evaluation glycosides
4
glycosides spacers
4

Similar Publications

Cold plasma generated by dielectric barrier discharge (DBD) and DBD combined with nebulized liquid microdroplets to generate plasma-activated mist (PAM) have shown the potential as a surface decontamination method for the food industry. The objective of this research was to measure the microbial inactivation caused by DBD and by PAM on tryptic soy agar (TSA) and on glass slides and to determine the efficacy of PAM on selected surfaces having different surface topographies. Tryptic soy agar in Petri dishes and on glass slides (surface roughness Pq = 0.

View Article and Find Full Text PDF

Background: Uveal melanoma (UM) is the most common primary intraocular malignancy in adults. The median overall survival time for patients who develop metastasis is approximately one year. In this study, we aim to leverage deep learning (DL) techniques to analyze digital cytopathology images and directly predict the 48 month survival status on a patient level.

View Article and Find Full Text PDF

Pathology has benefited from the rapid progress of image-digitizing technology during the last decade. However, the application of digital whole slide images (WSI) in forensic pathology still needs to be improved. WSI validation is crucial to ensure diagnostic performance, at least equivalent to glass slides and light microscopy.

View Article and Find Full Text PDF

Metallic biomaterials are extensively used in orthopedics and dentistry, either as implants or coatings. In both cases, metal ions come into contact with surrounding tissues causing a particular cell response. Here, we present a biofabricated tissue model, consisting of a hydrogel reinforced with a melt electrowritten mesh, to study the effects of bound and released metal ions on surrounding cells embedded in a hydrogel matrix.

View Article and Find Full Text PDF

Iris: A Next Generation Digital Pathology Rendering Engine.

J Pathol Inform

January 2025

University of Michigan Medical School, Department of Pathology, 2800 Plymouth Road, Ann Arbor, MI 48109-2800, USA.

Digital pathology is a tool of rapidly evolving importance within the discipline of pathology. Whole slide imaging promises numerous advantages; however, adoption is limited by challenges in ease of use and speed of high-quality image rendering relative to the simplicity and visual quality of glass slides. Herein, we introduce Iris, a new high-performance digital pathology rendering system.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!