Background: Enteryx implantation in the esophagus is an alternative therapy for patients with proton pump inhibitor (PPI) dependent GERD. Although this treatment resulted in highly significant improvement at 6 and 12 months, longer follow-up is needed to more fully assess the durability of these positive effects.
Methods: An open-label, international clinical trial was conducted in 144 PPI-dependent patients with GERD with follow-up at 6 and 12 months. In addition, the durability and the safety of the treatment were assessed for 24 months in 64 patients enrolled in a postapproval study. The primary study outcome measure was usage of PPI. Secondary outcomes in the multicenter trial were GERD health-related quality of life (GERD-HRQL) symptom score and esophageal acid exposure.
Results: At 12 months, PPI use was reduced > or =50% in 84%: 95% confidence interval (CI) [76%, 90%] and was eliminated in 73%: 95% CI[64%, 81%] of evaluable patients (intent-to-treat analysis 78%: 95% CI[70%, 84%] and 68%: 95% CI[60%, 76%], respectively). A GERD-HRQL < or =11 was attained in 78%: 95% CI[69%, 85%] of evaluable patients. Esophageal acid exposure (total time pH <4) was reduced by 31%: 95% CI[17%, 43%]. At 24 months, a > or =50% or greater reduction in PPI use was achieved in 72%: 95% CI[59%, 82%] and PPI use was eliminated in 67%: 95% CI[54%, 78%] of patients.
Conclusions: This investigation provides evidence for sustained effectiveness and safety of implantation of Enteryx in the esophagus in PPI-dependent patients with GERD.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/s0016-5107(04)02835-4 | DOI Listing |
Vascular
February 2023
Department of Vascular Interventional Radiology, Christiana Care Health System, Newark, DE, USA.
Purpose: This study aims to evaluate the safety and efficacy of novel approaches to type 2 endoleak access for the purpose of embolization using ethylene-vinyl-alcohol copolymer (EVOH) in patients with abdominal aortic aneurysm (AAA) sac expansion post endovascular abdominal aortic repair (EVAR).
Methods: A retrospective review of 43 consecutive patients (mean age = 80.2 ± 6.
Rofo
December 2021
Gefäßchirurgische Klinik, Evangelisches Krankenhaus Mülheim an der Ruhr, Germany.
Background: Type 2 endoleaks (T2EL) are the most frequent complication following endovascular aortic repair. Multiple studies primarily deal with the technical and clinical success of the embolization of persisting T2EL, thereby revealing controversial outcomes. Current reports rarely focus on the detailed execution of such a complex interventional procedure with respect to the difficult anatomic setting.
View Article and Find Full Text PDFVasa
October 2020
Department for Vascular and Endovascular Surgery and Munich Aortic Center (MAC), University Hospital rechts der Isar, Technical University of Munich, Munich, Germany.
: Type II endoleak (T2EL) after endovascular aortic repair is associated with AAA sac enlargements in up to 25%, reduction of attachment zones and rarely with aortic rupture. Indications for therapy and efficacy of interventions of T2EL are not clearly established. Transarterial embolization with application of ethylene-vinyl alcohol copolymer has been described with varying outcomes.
View Article and Find Full Text PDFVasc Endovascular Surg
January 2021
Department of Endovascular and Vascular Surgery, 21599Geisinger Medical Center, Danville, PA, USA.
Introduction: This study reports our experience with the use of an ethylene vinyl alcohol copolymer (Onyx™) for the treatment of type II endoleak after endovascular repair of abdominal aortic aneurysms (EVAR) in comparison to coils and cyanoacrylate glue.
Methods: Clinical data of all patients treated for type II endoleak following EVAR between 2009 and 2017 were retrospectively analyzed. Abdominal aortic aneurysm (AAA) diameter and AAA sac volume during follow-up were measured using computed tomography angiography (CTA).
Ann Vasc Surg
August 2020
Division of Vascular and Endovascular Surgery, Mayo Clinic, Rochester, MN. Electronic address:
Background: Type II endoleaks (T2ELs) are common following endovascular repair of abdominal aortic aneurysms (EVAR). Embolization with ethylene vinyl alcohol copolymer (Onyx) may present an effective treatment alternative for T2ELs. Due to limited data supporting its use, we sought to analyze outcomes of Onyx embolization for T2ELs.