Comparison of chromatographic ion-exchange resins IV. Strong and weak cation-exchange resins and heparin resins.

J Chromatogr A

Novo Nordisk A/S, Health Care Discovery and Development, Protein Separation, Hagedornsvej 1, DK-2820 Gentofte, Denmark.

Published: March 2005

AI Article Synopsis

  • A comparative study examined various chromatographic resins, including heparin and cation exchangers, analyzing factors like efficiency, binding strength, and capacity.
  • The experiments involved four different proteins, showing that pH had a minimal effect on retention for proteins with high isoelectric points, but certain resins had a notable decrease in retention as pH rose.
  • Results indicated that cation-exchange resins’ binding strength varied with ionic strength and protein type, with significant dynamic capacity utilized during operations, revealing potential substitutes for heparin resins in specific conditions.*

Article Abstract

A comparative study was performed on heparin resins and strong and weak cation exchangers to investigate the pH dependence, efficiency, binding strength, particle size distribution, static and dynamic capacity, and scanning electron microscopy pictures of chromatographic resins. The resins tested include: Heparin Sepharose FF, SP Sepharose FF, CM Sepharose FF, Heparin Toyopearl 650 m, SP Toyopearl 650 m, CM Toyopearl 650 m, Ceramic Heparin HyperD M, Ceramic S HyperD 20, and Ceramic CM HyperD F. Testing was performed with four different proteins: anti-FVII Mab (IgG), aprotinin, lysozyme, and myoglobin. Dependence of pH on retention was generally very low for proteins with high isoelectric point (pI), though some decrease of retention with increasing pH was observed for CM Ceramic HyperD F and S Ceramic HyperD 20. Binding of anti-FVII Mab with pI < 7.5 was observed on several resins at pH 7.5. Efficiency results show the expected trend of increasing dependence of the plate height with increasing flow rate of Ceramic HyperD resins followed by Toyopearl 650 m resins and the highest flow dependence of the Sepharose FF resins corresponding to their pressure resistance. Determination of particle size distribution by two independent methods, coulter counting and SEM, was in good agreement. Binding strength of cation-exchange resins as a function of ionic strength varies depending on the protein. Binding and elution at high salt concentration may be performed with Ceramic HyperD resins, while binding and elution at low salt concentration may be performed with model proteins on heparin resins. Employing proteins with specific affinity for heparin, a much stronger binding is observed, however, some cation exchangers may still be good substitutions for heparin resins. Dynamic capacity at 10% breakthrough compared to static capacity measurements and dynamic capacity displays that approximately 40-80% of the total available capacity is utilized during chromatographic operation depending on flow rate. A general good agreement was obtained between results of this study and data obtained by others. Results of this study may be used in the selection of resins for testing during protein purification process development.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.chroma.2004.11.094DOI Listing

Publication Analysis

Top Keywords

ceramic hyperd
24
heparin resins
16
toyopearl 650
16
resins
15
dynamic capacity
12
hyperd ceramic
12
resins strong
8
strong weak
8
cation-exchange resins
8
heparin
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!