Stability of miniature electromagnetic tracking systems.

Phys Med Biol

University Hospital of Cranio-Maxillofacial and Oral Surgery, Medical University of Vienna, Waehringer Guertel 18-20, 1090 Vienna, Austria.

Published: May 2005

This study aims at a comparative evaluation of two recently introduced electromagnetic tracking systems under reproducible simulated operating-room (OR) conditions: the recently launched Medtronic StealthStation, Treon-EM and the NDI Aurora. We investigate if and to what extent these systems provide improved performance and stability in the presence of surgical instruments as possible sources of distortions compared with earlier reports on electromagnetic tracking technology. To investigate possible distortions under pseudo-realistic OR conditions, a large Langenbeck hook, a dental drill with its handle and an ultrasonic (US) scanhead are fixed on a special measurement rack at variable distances from the navigation sensor. The position measurements made by the Treon-EM were least affected by the presence of the instruments. The lengths of the mean deviation vectors were 0.21 mm for the Langenbeck hook, 0.23 mm for the drill with handle and 0.56 mm for the US scanhead. The Aurora was influenced by the three sources of distortion to a higher degree. A mean deviation vector of 1.44 mm length was observed in the vicinity of the Langenbeck hook, 0.53 mm length with the drill and 2.37 mm due to the US scanhead. The maximum of the root mean squared error (RMSE) for all coordinates in the presence of the Langenbeck hook was 0.3 mm for the Treon and 2.1 mm for the Aurora; the drill caused a maximum RMSE of 0.2 mm with the Treon and 1.2 mm with the Aurora. In the presence of the US scanhead, the maximum RMSE was 1.4 mm for the Treon and 5.1 mm for the Aurora. The new generation of electromagnetic tracking systems has significantly improved compared to common systems that were available in the middle of the 1990s and has reached a high level of technical development. We conclude that, in general, both systems are suitable for routine clinical application.

Download full-text PDF

Source
http://dx.doi.org/10.1088/0031-9155/50/9/011DOI Listing

Publication Analysis

Top Keywords

electromagnetic tracking
16
langenbeck hook
16
tracking systems
12
treon aurora
12
drill handle
8
scanhead maximum
8
maximum rmse
8
rmse treon
8
systems
6
aurora
5

Similar Publications

Wearable nanocomposite stretch sensors are an exciting new development in biomaterials for biomechanical motion-tracking technology, with applications in the treatment of low back pain, knee rehabilitation, fetal movement tracking, and other fields. When strained, the resistance of the low-cost sensors is reduced, enabling human motion to be monitored using a suitable sensor array. However, current sensor technologies have exhibited significant drift, in the form of increased electrical resistance, if left stored in typical room conditions.

View Article and Find Full Text PDF

Electrical Bioimpedance-Based Monitoring of Intracochlear Tissue Changes After Cochlear Implantation.

Sensors (Basel)

November 2024

Department of Otorhinolaryngology, Head & Neck Surgery, University Hospital Zurich, University of Zurich, 8091 Zurich, Switzerland.

Background: This study examined electrical bioimpedance as a biomarker for intracochlear tissue changes after cochlear implant surgery, comparing monopolar, three-point, and four-point impedance measurements over time and evaluating different measurement systems and approaches.

Methods: Impedance measurements were obtained from 21 participants during surgery and at four postoperative stages. Monopolar impedances were recorded using the Bionic Ear Data Collection System (BEDCS) and the Active Insertion Monitoring (AIM) system.

View Article and Find Full Text PDF

Photonic Band Gap Engineering by Varying the Inverse Opal Wall Thickness.

Int J Mol Sci

December 2024

Institute of Physical Metallurgy, Metal Forming and Nanotechnology, University of Miskolc, H-3515 Miskolc, Hungary.

We demonstrate the band gap programming of inverse opals by fabrication of different wall thickness by atomic layer deposition (ALD). The opal templates were synthesized using polystyrene and carbon nanospheres by the vertical deposition method. The structure and properties of the TiO inverse opal samples were investigated using Scanning Electron Microscope (SEM) and Focused Ion Beam Scanning Electron Microscopy (FIB-SEM), Energy Dispersive X-ray analysis (EDX), X-ray Diffraction (XRD) and Finite Difference Time Domain (FDTD) simulations.

View Article and Find Full Text PDF

Tracking head movement inside an MR scanner using electromagnetic coils.

Heliyon

July 2024

Sir Peter Mansfield Imaging Centre, School of Physics and Astronomy, University of Nottingham, Nottingham, NG7 2RD, UK.

Prospective motion corrections in brain imaging for MRI are fairly challenging. Monitoring involuntary head movement inside MR scanner is crucial for prospective motion correction. This initial study delves into utilizing simulations to track the head's movements within an MRI scanner, achieved by measuring induced voltage changes from time-varying magnetic field gradients in head-mounted coils.

View Article and Find Full Text PDF

Precise tracking of axonal transport is key to deciphering neuronal functions. To achieve long-term imaging at both ultrastructural and macroscopic resolutions, it is critical to develop fluorescent transport tracers with high photostability and biocompatibility. Herein, we report the investigation of nanographene (NG)-based polymeric nanoparticles (NPs) as near-infrared (NIR)-emissive neuronal tracers.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!