A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@remsenmedia.com&api_key=81853a771c3a3a2c6b2553a65bc33b056f08&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Quality control in urinary stone analysis: results of 44 ring trials (1980-2001). | LitMetric

Urinary stone analysis is the most important diagnostic step after stone removal from the body. The methods employed for these analyses are based on diverse analytical principles. Chemical methods are used for detecting individual ions. Infrared spectroscopy is used for examining molecular structures, and X-ray diffraction for determination of the crystalline structure of a substance. Since 1980, a twice-yearly ring trials quality control survey has been on offer to examine the quality of urinary stone analyses. A summary of the results of 44 ring trials (1980-2001) has been compiled for individual pure substances and binary (two-component) mixtures. On average, 100 laboratories have participated in these ring trials. Initially, over 80% of the participants carried out their analyses using chemical methods. In 2001, this figure decreased to a mere 13%. In contrast, a progressive increase in the use of infrared spectroscopy was observed, up to 79% of all participants employed this method. X-Ray diffraction was only employed in a small number of specialised laboratories (5-9%). The chemical methods produced a very high proportion of errors (6.5-94%) with both the pure substances and binary mixtures, whereas high error rates for infrared spectroscopy and X-ray diffraction were confined to individual substances only. Due to the poor results in the ring trials, the majority of laboratories stopped using chemical analysis, which is now considered to be obsolete. Regarding mixtures, error rates of over 10% also occurred with infrared spectroscopy and X-ray diffraction. Ring trials are indispensable for the quality management of urinary stone analysis.

Download full-text PDF

Source
http://dx.doi.org/10.1515/CCLM.2005.051DOI Listing

Publication Analysis

Top Keywords

ring trials
24
urinary stone
16
infrared spectroscopy
16
x-ray diffraction
16
stone analysis
12
chemical methods
12
quality control
8
trials 1980-2001
8
pure substances
8
substances binary
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!