X-ray tubes have superseded radionuclide sources for dual photon absorptiometry of the spine and hip. However, the use of a polyenergetic spectrum is a potential source of error for x-ray absorptiometers since beam hardening may result in a nonlinear measurement scale for bone mineral density (BMD). A quantitative study of the effects of beam hardening on measurements made with a commercial dual energy x-ray scanner has been performed. Bone was represented by layers of aluminum of linearly increasing thickness which were scanned under water thicknesses ranging from 0 to 25 cm to represent different body thicknesses of soft tissue. Beam hardening had two effects on measured BMD: (i) at a constant true BMD, measured BMD varied with water thickness; (ii) at a constant water thickness, the BMD scale was not precisely linear. For conditions appropriate to spine and hip studies (BMD) values in the range 0.7 to 1.4 g/cm2 and body thickness between 15 and 25 cm) the maximum deviation of measured BMD from a linear scale was 0.023 g/cm2, while the root-mean-square deviation (0.01 g/cm2) was comparable to the measurement precision for a spine or femoral neck scan (about 1%). The largest departures from linearity were found to occur at the thinnest water thicknesses for BMD values in the range 0.2 to 0.6 g/cm2. The effect of scale nonlinearity on the results of longitudinal studies was examined: for a spine scan at 20-cm body thickness, measured changes in BMD slightly overestimated the true change and implied an error of 0.15%/year for a measurement of a true rate of loss of 3% year in a postmenopausal woman.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1118/1.596834 | DOI Listing |
Materials (Basel)
December 2024
Department of Materials and Fabrication Engineering, Politehnica University Timisoara, Bulevardul Mihai Viteazul nr.1, 300222 Timișoara, Romania.
This paper explores the enhancement of cavitation and corrosion resistance in cast stainless steel through laser beam surface remelting. The influence of laser treatment on material properties was assessed by analyzing the microstructure using optical microscopy, electron microscopy, and X-ray diffraction. Cavitation erosion was evaluated in tap water using an ultrasonic vibration setup, following ASTM G32-2016 standards.
View Article and Find Full Text PDFBioengineering (Basel)
December 2024
Department of Radiology, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan 430030, China.
This study aimed to optimize CT esophagography by identifying effective oral contrast dilution ratios and exploring the advantages of dual-energy CT (DECT) over conventional CT for improving image quality. Ex vivo experiments using iodine contrast agents (320-400 mgI/mL) at 21 dilution ratios were scanned at three voltages, with additional dual-energy scans generating various reconstruction images. Image quality was assessed both objectively and subjectively.
View Article and Find Full Text PDFImaging Sci Dent
December 2024
Department of Oral Diagnosis, Division of Oral Radiology, Piracicaba Dental School, University of Campinas, Piracicaba, SP, Brazil.
Purpose: This study was performed to evaluate the expression of beam hardening artifacts generated by high atomic number materials in stitched cone-beam computed tomography (CBCT) images, compared to the traditional acquisition mode.
Materials And Methods: CBCT volumes were acquired using an acrylic resin phantom embedded with pairs of cylinders made from amalgam dental alloy, cobalt-chromium alloy, gutta-percha, titanium, and zirconium. These cylinders were placed within the overlapping zones of the stitching reconstruction area.
J Med Imaging (Bellingham)
December 2024
University of Houston, Department of Physics, Houston, Texas, United States.
Purpose: Photon counting detectors offer promising advancements in computed tomography (CT) imaging by enabling the quantification and three-dimensional imaging of contrast agents and tissue types through simultaneous multi-energy projections from broad X-ray spectra. However, the accuracy of these decomposition methods hinges on precise composite spectral attenuation values that one must reconstruct from spectral micro-CT. Errors in such estimations could be due to effects such as beam hardening, object scatter, or detector sensor-related spectral distortions such as fluorescence.
View Article and Find Full Text PDFMed Phys
December 2024
ICube Laboratory, University of Strasbourg UMR 7357 CNRS, Strasbourg, France.
Background: Percutaneous image-guided cementoplasty is a medical procedure for strengthening bones structurally altered by disease, such as osteolytic metastasis. This procedure involves injecting biocompatible liquid bone cement, through one or more trocars into the damaged bone. Within a few minutes the bone cement hardens and restores the rigidity of the bony structure.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!