Visual evoked potentials (VEPs) were recorded in response to a vernier onset/offset target presented to one eye that was combined with matching static targets in the other eye. The monocular response was dominated by a negative peak at 160 ms that occurred after a set of offsets was introduced into a one-dimensional random bar pattern. The static targets produced no discernible VEP response by themselves, but when fused binocularly with the oscillating vernier target, they produced shifts in perceived visual direction that influenced the VEP response. A vernier target fused with static vertical bars was perceived to alternate in depth between a flat surface and one broken into two interleaved surfaces. The response to this "surface-breaking" was as large or larger than the response to the monocular vernier offset. This response was much reduced when the oscillating vernier was fused with a static offset vernier (5' offset) that produced a percept of segregated regions moving in depth. Apparently, the VEP is strongly driven by shifts in visual direction that alter surface, texture, or contour contiguity.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1167/5.1.4 | DOI Listing |
J Comp Neurol
January 2025
Department of Biotechnology, Bhupat and Jyoti Mehta School of Biosciences, Indian Institute of Technology Madras, Chennai, Tamil Nadu, India.
Direction selectivity is a fundamental feature in the visual system. In the retina, direction selectivity is independently computed by ON and OFF circuits. However, the advantages of extracting directional information from these two independent circuits are unclear.
View Article and Find Full Text PDFEur Spine J
January 2025
Department of Traditional Chinese Medicine, Dongguan Binhaiwan Central Hospital, Dongguan City, Guangdong Province, 523905, China.
Objective: To explore the efficacy and safety of the direct inferior endplate approach in percutaneous endoscopic interlaminar discectomy (PEID) for the treatment of L5-S1 disc herniation.
Methods: This was a retrospective analysis of 116 patients with L5-S1 disc herniation treated with PEID; 74 patients underwent surgery via the direct inferior endplate approach (group A), and 42 patients underwent surgery via the indirect approach (group B). The number of intraoperative fluoroscopy exposures, establishment channel time, operation time, postoperative visual analogue scale (VAS) score, and Oswestry Disability Index (ODI) were compared between the 2 groups.
Curr Top Dev Biol
January 2025
Department of Pharmacology, School of Medicine, Case Western Reserve University, Cleveland, OH, United States. Electronic address:
Animals perceiving light through visual pigments have evolved pathways for absorbing, transporting, and metabolizing the precursors essential for synthesis of their retinylidene chromophores. Over the past decades, our understanding of this metabolism has grown significantly. Through genetic manipulation, researchers gained insights into the metabolic complexity of the pathways mediating the flow of chromophore precursors throughout the body, and their enrichment within the eyes.
View Article and Find Full Text PDFJ Invertebr Pathol
January 2025
Department of Entomology and Acarology, Escola Superior de Agricultura 'Luiz de Queiroz', University of São Paulo (ESALQ-USP), Av. Pádua Dias, 11, Piracicaba, SP CEP 13418-900, Brazil.
The ovicidal effect of entomopathogenic fungi and the mechanisms involved are still debated. The hypothesis that the metabolic activity of germinating conidia can cause insect embryos to become unviable without physical penetration has been proposed. Here, we demonstrated that Metarhizium anisopliae and Metarhizium pingshaense, differently from Beauveria bassiana, reduced the percentage of nymphs hatching to less than 3%.
View Article and Find Full Text PDFBiomed Phys Eng Express
January 2025
Children's Hospital of Eastern Switzerland, Claudiusstrasse 6, St.Gallen, 9006, SWITZERLAND.
Mapping the myomagnetic field of a straight and easily accessible muscle after electrical stimulation using triaxial optically pumped magnetometers (OPMs) to assess potential benefits for magnetomyography (MMG). Approach: Six triaxial OPMs were arranged in two rows with three sensors each along the abductor digiti minimi (ADM) muscle. The upper row of sensors was inclined by 45° with respect to the lower row and all sensors were aligned closely to the skin surface without direct contact.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!