A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Atrial pacing should be used more frequently in sinus node disease. | LitMetric

Background: Single lead atrial (AAI(R)) pacing for sick sinus syndrome provides physiological pacing and is less expensive than a dual chamber system. Compared with ventricular-based pacing, it maintains the normal cardiac depolarization sequence, is associated with less atrial fibrillation and heart failure, and avoids pacemaker syndrome. We sought whether it is possible to select patients for AAI(R) pacing with a low likelihood of subsequent ventricular pacing, and whether this approach was cost-effective.

Methods: A retrospective review was conducted of AAI(R) pacemaker implantations. Patients requiring a further procedure for insertion of a ventricular lead (for DDD(R) or VVI(R) pacing) were compared with those who remained atrially paced.

Results: 2.7% (117 of 4,366) of implants were AAI(R), compared with less than 1% overall for New Zealand and Australia. During follow-up of 3.5 (2.3, 7.7) years, insertion of a ventricular lead was required in 14 (12%), and was more likely in those with pre-existing PR interval >0.20 seconds (odds ratio 7.8, P = 0.003) or left bundle branch block (LBBB, odds ratio 17, P = 0.037). Right bundle branch block, left anterior fascicular block, or history of paroxysmal atrial fibrillation were not more frequent in the group requiring ventricular pacing, and preimplantation Wenckebach point was not different. The most efficient strategy was initial AAIR implantation in all except those with LBBB or PR interval >0.20 seconds. Compared with routine DDDR implantation, cost was reduced by 20%, with a 1.4% annual incidence of further procedures.

Conclusion: AAIR is the appropriate pacing choice for sick sinus syndrome without LBBB or PR interval >0.20 seconds.

Download full-text PDF

Source
http://dx.doi.org/10.1111/j.1540-8159.2005.08672.xDOI Listing

Publication Analysis

Top Keywords

interval >020
12
>020 seconds
12
pacing
8
aair pacing
8
sick sinus
8
sinus syndrome
8
atrial fibrillation
8
ventricular pacing
8
insertion ventricular
8
ventricular lead
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!