The present study present a three-dimensional virtual simulation method to evaluate the fit-and-fill effect of the insertion of a trochanteric gamma nail (TGN) in 98 Thai dadaveric proximal femora. The circular best fit of the 2-dimensional cross-section of the femoral canal and the nail at 4 levels [d100, d120, d140 and d160] which were located at 100, 120, 140 and 160 mm distal to the tip of the greater trochanter were calculated. The evaluation of each level included, 1) the diameters of the medullary canal, 2) the percentage of area filled by the nail in the unreamed medullary canal, 3) the minimal reamer diameter that required enlargement of the canal to accommodate TGN insertion, 4) the minimal inner cortical reaming thickness that needed to be removed, 5) the percentage of cortical bone area that needed to be removed prior to nail insertion and 6) the deviation of the nail center from the center of the medullary canal. The results showed that at 4 studied locations the diameter of unreamed medullary canal averaged 10.3 to 11.8 mm. The nail cross-section that could fill the medullary canal averaged 86.9-95.1%. The minimal reaming diameter for the medullary canal to accommodate the TGN insertion averaged 11.3 to 12.3 mm. The inner cortical thickness that should be removed averaged 0.6 to 0.8 mm. The cortical bone that needed to be removed averaged 13.6 to 19.3% of the total cortical area. The deviation of the nail center from the canal center averaged 0.3 to 0.8 mm. The present study showed some mismatching of the TGN to that of the Thai proximal femur. Appropriate reaming to prepare the medullary canal should be considered prior to TGN insertion to prevent technical problem. Future re-design of the implant may be considered for Thai patients.
Download full-text PDF |
Source |
---|
Am J Vet Res
December 2024
Department of Small Animal Surgery, ONIRIS Nantes-Atlantic College of Veterinary Medicine, Food Science, and Engineering, Nantes, France.
Objective: To study the morphology of canine and feline femurs and tibias in lateral radiographic projections and assess their compatibility with either a straight or a curved full-length interlocking nail (ILN).
Methods: Lateral projection radiographs of 50 tibias and 50 femurs (10 cats and 40 dogs per bone) were used to measure the minimum and maximum radius of curvature of an ILN compatible with each bone. These radii were defined by cranial and caudal endosteal points at the proximal entry point of the nail, at the isthmus, and at the most distal point of the ILN insertion into the femoral or tibial metaphysis.
J Long Term Eff Med Implants
December 2024
St. Joseph's Hospital, Paterson, New Jersey, USA.
Prosthetic bone and joint infections are difficult to treat with varying levels of success with standard therapy. Synthetic calcium sulfate carrier, to which specific antibiotics can be added, can be utilized as an alternative drug delivery system in these cases. We have reviewed clinical outcomes using commercially available pure synthetic calcium sulfate dissolvable beads (Stimulan) loaded with antibiotics in 143 patients undergoing orthopedic surgery for prevention and treatment of joint infection.
View Article and Find Full Text PDFPlast Reconstr Surg Glob Open
December 2024
Department of Bone and Joint Surgery, Peking University Shenzhen Hospital, Shenzhen, China.
A 57-year-old man presented with a tibial shaft fracture treated with tibial intramedullary nail fixation and plate and screw fixation for fibular fracture. Two weeks postoperatively, the patient developed skin sloughing with exposed bone and metal at the fracture site. Three weeks postoperatively, a physical examination revealed swelling of the left lateral malleolus and lower leg, a skin defect of approximately 3 × 5 cm at the lower third of the left tibia with an exposed fracture site and hardware in between the fracture fragments.
View Article and Find Full Text PDFJ Orthop Case Rep
December 2024
Department of Orthopaedics, Postgraduate Institute of Medical Education and Research, Chandigarh, India.
Introduction: Delayed union, non-union, and unstable fixation can lead to fatigue fractures of orthopedic implants. Breakages typically occur at the fracture site or locking screw insertion, acting as stress concentration foci. This case report highlights a rare instance of a 3-part broken proximal femoral nail (PFN), extracted using a corticotomy-assisted method without knee joint violation.
View Article and Find Full Text PDFOrthop Traumatol Surg Res
November 2024
Hôtel Dieu, service d'orthopédie-traumatologie, 1, place Alexis-Ricordeau, 44093 Nantes Cedex 1, France. Electronic address:
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!