The quantitative assessment of cardiac motion is a fundamental concept to evaluate ventricular malfunction. We present a new optical-flow-based method for estimating heart motion from two-dimensional echocardiographic sequences. To account for typical heart motions, such as contraction/expansion and shear, we analyze the images locally by using a local-affine model for the velocity in space and a linear model in time. The regional motion parameters are estimated in the least-squares sense inside a sliding spatiotemporal B-spline window. Robustness and spatial adaptability is achieved by estimating the model parameters at multiple scales within a coarse-to-fine multiresoluion framework. We use a wavelet-like algorithm for computing B-spline-weighted inner products and moments at dyadic scales to increase computational efficiency. In order to characterize myocardial contractility and to simplify the detection of myocardial dysfunction, the radial component of the velocity with respect to a reference point is color coded and visualized inside a time-varying region of interest. The algorithm was first validated on synthetic data sets that simulate a beating heart with a speckle-like appearance of echocardiograms. The ability to estimate motion from real ultrasound sequences was demonstrated by a rotating phantom experiment. The method was also applied to a set of in vivo echocardiograms from an animal study. Motion estimation results were in good agreement with the expert echocardiographic reading.

Download full-text PDF

Source
http://dx.doi.org/10.1109/tip.2004.838709DOI Listing

Publication Analysis

Top Keywords

motion
5
myocardial motion
4
motion analysis
4
analysis b-mode
4
b-mode echocardiograms
4
echocardiograms quantitative
4
quantitative assessment
4
assessment cardiac
4
cardiac motion
4
motion fundamental
4

Similar Publications

Purpose: This study aimed to investigate whether combining the analysis of different magnetic resonance imaging (MRI) signs enhances the diagnostic accuracy of lateral meniscus posterior root tears (LMPRTs) in patients with anterior cruciate ligament (ACL) injuries. We hypothesised that analysing the cleft, ghost and truncated triangle signs and lateral meniscus extrusion (LME) measurement together would improve the preoperative MRI-based diagnosis of LMPRTs.

Methods: This retrospective study used prospectively collected registry data from two academic centres, including patients undergoing primary or revision ACL reconstruction (ACLR) and LMPRT repair.

View Article and Find Full Text PDF

Background: Ultrasound lung surface motion measurement is valuable for the evaluation of a variety of diseases. Speckle tracking or Doppler-based techniques are limited by the loss of visualization as a tracked point moves under ribs or is dependent.

Methods: We developed a synthetic lateral phase-based algorithm for tracking lung motion to overcome these limitations.

View Article and Find Full Text PDF

Background: Spacer-type tibial osteotomy have been proven a novel and effective osteotomy to treat osteoarthritis, while lack of comparison with other surgical methods in younger patients. This study aims to evaluate the short-term clinical outcomes of spacer-type tibial osteotomy versus open wedge high tibial osteotomy (OWHTO) and unicompartmental knee arthroplasty (UKA) for Kellgren-Lawrence (K-L) grade 3-4 osteoarthritis (OA) in patients younger than 65 years.

Methods: This retrospective study analyzed a total of 224 patients with K-L grade 3-4 knee OA treated from March 2018 to November 2020.

View Article and Find Full Text PDF

Cilia assembly and function rely on the bidirectional transport of components between the cell body and ciliary tip via Intraflagellar Transport (IFT) trains. Anterograde and retrograde IFT trains travel along the B- and A-tubules of microtubule doublets, respectively, ensuring smooth traffic flow. However, the mechanism underlying this segregation remains unclear.

View Article and Find Full Text PDF

Objective: To evaluate whether, in late pregnancy, the cerebral Doppler can identify very small fetuses that are less likely to experience intrapartum compromise (IC).

Material And Methods: This was a retrospective study of 282 singleton pregnancies that underwent an ultrasound scan at 32 + 0- 40 + 6 weeks and were delivered after induction, or spontaneous onset of labor. Very small fetuses were defined as fetuses with estimated weight less than the 3rd centile.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!