We describe three patients who required mechanical ventilation for severe acute exacerbations of obstructive airways disease. When treatment with sedatives and muscle relaxants was withdrawn, they exhibited profound generalized weakness and consequently required prolonged ventilation despite resolution of the airway obstruction. Clinical features were variable, but none of the patients developed failure of other organs and infection was confined to the lungs. All had electrophysiologic evidence of a predominantly motor axonal syndrome. One patient in whom sensory action potentials were abnormal may represent an unusually severe case of critical illness neuropathy occurring in the absence of systemic sepsis and multiple organ failure. In the other two cases, this diagnosis is made less likely by the complete absence of sensory involvement and in these patients the lesion appeared to be either in the most distal portion of the motor neuron or at the neuromuscular junction. In all three patients, resolution was slow but eventually complete. The etiology of the condition is not clear, but it seems to be distinct from the acute myopathy previously described in asthmatics who had received mechanical ventilation. It is important to recognize this phenomenon to avoid erroneous conclusions about the likelihood of the patient recovering from ventilator dependence. A prolonged weaning period is to be expected in such cases.