Computed tomography and cross-sectional anatomy of the thorax in clinically normal dogs.

Am J Vet Res

Department of Medical Imaging, Faculty of Veterinary Medicine, Ghent University, 9820 Merelbeke, Belgium.

Published: March 2005

Objective: To provide a detailed anatomic description of the thorax in clinically normal dogs by means of computed tomography.

Animals: 4 clinically normal adult German Shepherd Dogs weighing 28 to 37 kg.

Procedure: Dogs were anesthetized and positioned in ventral recumbency for computed tomographic (CT) examination of the thorax. A CT image from the thoracic inlet to the diaphragm was made by use of a third-generation scanner with a slice thickness of 5 mm. Individual images were reviewed by use of soft tissue (window width, 250 Hounsfield units; window level, 35 Hounsfield units) and lung (window width, 1,000 Hounsfield units; window level, -690 Hounsfield units) settings. One dog, weighing 28 kg, was euthanatized, bound on a wooden frame in the same position as used for CT examination, and frozen at -14 degrees C until solid. By use of an electric band saw, the frozen thorax was sectioned at 10-mm-thick intervals. Slab sections were immediately cleaned, photographed, and compared with corresponding CT images.

Results: Anatomic sections were studied, and identified anatomic structures were matched with structures on corresponding CT images. Except for some blood vessels and details of the heart, most of the bony and soft tissue structures of the thorax discerned on anatomic slices could be found on matched CT images.

Conclusions And Clinical Relevance: Because CT images provide detailed information on most structures of the canine thorax, results of our study could be used as a guide for evaluation of CT images of the thorax of dogs with thoracic diseases.

Download full-text PDF

Source
http://dx.doi.org/10.2460/ajvr.2005.66.512DOI Listing

Publication Analysis

Top Keywords

hounsfield units
16
clinically normal
12
thorax clinically
8
normal dogs
8
provide detailed
8
soft tissue
8
window width
8
units window
8
window level
8
thorax
7

Similar Publications

Purpose: There is a growing interest in using computed tomography (CT) scans to opportunistically assess bone mineral density via Hounsfield units (HU). Previous studies have shown lower HU in patients with vertebral compression fractures (VCFs) and that HU can predict pre-existing VCFs. This study evaluated whether HU from CT scans can predict the number of prevalent VCFs.

View Article and Find Full Text PDF

It is rare to find free floating fat droplets in the cerebral spinal fluid (CSF) spaces of the brain. When fat droplets are seen in the CSF spaces, the most common cause is the rupture of a dermoid cyst. Dermoid cysts are congenital inclusion cysts that form during the neural tube closure between the third and fifth weeks of embryogenesis.

View Article and Find Full Text PDF

Background: This study aimed to evaluate the outcomes and role of lymphadenectomy in hypervascular intrahepatic cholangiocarcinoma (ICC) quantified using the arterial phase of contrast-enhanced computed tomography (CT).

Methods: Consecutive patients with mass-forming (MF) or predominantly MF type ICC who underwent surgical resection from 2000 to 2019 were retrospectively analyzed. Using the image of the late arterial phase, CT-vascularity was calculated by dividing the CT value of the tumor (Hounsfield units) with that of the liver parenchyma.

View Article and Find Full Text PDF

Background: Bronchial cysts (BCs) can be difficult to diagnose because of non-specific site of occurrence and heterogeneous density of cyst content in some patients. We present herein a BC case with such nonspecific findings.

Case: A 23-year-old man referred to our hospital because of an abnormal chest image during a mass-screening.

View Article and Find Full Text PDF

Evaluation of Pedicle Screw Position on Computerized Tomography Using Three-Dimensional Reconstruction Software.

Medicina (Kaunas)

December 2024

Spine Center and Department of Orthopedic Surgery, Seoul National University College of Medicine, Seoul National University Bundang Hospital, Seongnam 13620, Republic of Korea.

: Recent advances in intraoperative navigation systems have improved the accuracy of pedicle screw placement in spine surgery. However, many hospitals have limited access to these advanced technologies due to resource constraints. In such settings, postoperative computed tomography (CT) evaluation remains crucial for assessing screw placement and related potential complications.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!