A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Comparison of the ovine and porcine animal models for biocompatibility testing of vascular prostheses. | LitMetric

Objective: Evaluation of the pig and sheep models for biocompatibility investigations of vascular prostheses (VP).

Design: Comparative analysis of animal experimental investigations involving two different animal models.

Materials And Methods: Commercially available polyester vascular prostheses (PET-VP) were implanted into two different animal models (infrarenal porcine aorta and ovine carotid artery). The costs, surgical handling, patency rate, and healing on the basis of macroscopic, microscopic, and immunohistochemical criteria were analyzed over a period of 3 months.

Results: Handling and operating times (63 +/- 10 versus 76 +/- 16 min; P = 0.125) did not differ significantly. The cost of the two animal models was comparable. Integration of the VP was complete in the sheep model, but varied in the pig model (two complete, four incomplete). Complete endothelialization of all VPs was observed in the pig, which contrasted with the sheep with complete (circular) endothelialization only in the region of the anastomosis. The thickness of neointima in the region of the anastomosis differed insignificantly; immunohistochemically, only periprosthetic Ki67 was significantly reduced (28.7 +/- 9.9 versus 6 +/- 0.9%; P = 0.002) in the sheep.

Conclusions: In the porcine model, extremely good endothelialization of the VP was observed, with formation of a rapid neointimal hyperplasia. The ovine model was characterized by the fact that postoperative follow-up investigations were easy to perform. Complete endothelialization was not observed.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jss.2004.10.021DOI Listing

Publication Analysis

Top Keywords

animal models
12
vascular prostheses
12
models biocompatibility
8
+/- versus
8
versus +/-
8
complete endothelialization
8
region anastomosis
8
endothelialization observed
8
animal
5
complete
5

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!