Pulsed mid-infrared (6.45 microm) radiation has been shown to cut soft tissue with minimal collateral damage (<40 microm); however, the mechanism of ablation has not been elucidated to date. The goal of this research was to examine the role of the unique pulse structure of the Vanderbilt Mark-III free-electron laser (FEL) and its role in the efficient ablation of soft tissue with minimal collateral damage. The effect of the picosecond micropulse was examined by running the native FEL pulse structure through a pulse stretcher in order to increase the micropulse length from 1 ps up to approximately 200 ps. This allowed us to determine whether or not the picosecond train of micropulses played any role in the ablation process. The ablation threshold was determined for water and mouse dermis for each micropulse length. While the results of the analysis showed a statistically significant difference between 1 and 200 ps, the average per cent difference amounts to only 28% and is not proportional to the 200-fold drop in peak irradiance. The ablation efficiency was also measured on gelatin and mouse dermis for the different micropulse lengths. A small but statistically significant difference was observed between 1 and 200 ps, with the 200 ps pulse being more efficient on gelatin, and with the opposite trend for mouse dermis. We have shown that there is a small effect of micropulse duration of the FEL on the ablation process; however, this effect is negligible between 1 and 200 ps given that there is a 200-fold decrease in peak intensity. These results suggest that as we move forward in developing alternative laser sources for tissue ablation to replace the FEL, the picosecond micropulse structure is not a critical parameter that needs to be duplicated.

Download full-text PDF

Source
http://dx.doi.org/10.1088/0031-9155/50/8/016DOI Listing

Publication Analysis

Top Keywords

free-electron laser
4
laser pulse
4
pulse structure
4
structure mid-infrared
4
mid-infrared soft-tissue
4
soft-tissue ablation
4
ablation ablation
4
ablation metrics
4
metrics pulsed
4
pulsed mid-infrared
4

Similar Publications

We theoretically investigate the impact of nonlinear dispersion of crystals and multilayers used in Laue-type pulse compressors (LPCs) on chirped x-ray pulse compression, as well as the optimization method for the configuration of LPCs. We also study the application of LPCs to compress chirped x-ray free-electron laser pulses based on the parameters of LCLS-II-HE. The results show that the optimal thickness is half of the Pendellosung period, yielding the best compressor performance with minimal impact from the nonlinear dispersion.

View Article and Find Full Text PDF

We report the use of streaming data interfaces to perform fully online data processing for serial crystallography experiments, without storing intermediate data on disk. The system produces Bragg reflection intensity measurements suitable for scaling and merging, with a latency of less than 1 s per frame. Our system uses the CrystFEL software in combination with the ASAP::O data framework.

View Article and Find Full Text PDF

In this work, we theoretically explore whether a parity-violating/chiral light-matter interaction is required to capture all relevant aspects of chiral polaritonics or if a parity-conserving/achiral theory is sufficient (e.g., long-wavelength/dipole approximation).

View Article and Find Full Text PDF

PGMweb: an online tool for visualizing the X-ray beam path through plane grating monochromators.

J Synchrotron Radiat

January 2025

Diamond Light Source, Harwell Science and Innovation Campus, Didcot, Oxfordshire OX11 0DE, United Kingdom.

We present here a newly developed software tool (called PGMweb) for computing and simulating the X-ray beam path through a plane grating monochromator (PGM), a key component in soft X-ray beamlines at modern synchrotron and free-electron laser facilities. A historical overview of the development of PGMs is presented, with special attention dedicated to the collimated PGM optical scheme found at several X-ray facilities worldwide. The analytical expressions that fully describe the geometry of a PGM are derived and have been implemented as functions in a Python library (pyplanemono).

View Article and Find Full Text PDF

The Heisenberg-RIXS instrument at the European XFEL.

J Synchrotron Radiat

January 2025

Institute Methods and Instrumentation for Synchrotron Radiation Research, Helmholtz-Zentrum Berlin für Materialien und Energie GmbH, Albert-Einstein-Straße 15, 12489 Berlin, Germany.

Resonant inelastic X-ray scattering (RIXS) is an ideal X-ray spectroscopy method to push the combination of energy and time resolutions to the Fourier transform ultimate limit, because it is unaffected by the core-hole lifetime energy broadening. Also, in pump-probe experiments the interaction time is made very short by the same core-hole lifetime. RIXS is very photon hungry so it takes great advantage from high-repetition-rate pulsed X-ray sources like the European XFEL.

View Article and Find Full Text PDF