Perioperative contamination in primary total hip arthroplasty.

Clin Orthop Relat Res

Department of Orthopaedic Surgery, University Hospital Groningen, PO Box 30001, 9700 RB Groningen, The Netherlands.

Published: April 2005

Unlabelled: All surgical procedures have the risk of microbial contamination. However, procedures in which prosthetic materials are involved have a high risk for future infectious problems because of the protection offered by the biofilm mode of growth. Studies of perioperative contamination have been done on involved surgical instruments, but whether these instruments transmit contamination to the prosthesis or future site of the prosthesis is not known. The aim of this study was to detect possible bacterial contamination in total hip arthroplasty through instruments that are used at the direct site of implantation during the primary procedure. Samples of the broaches used for preparing the acetabulum and femur, and samples of the reamed acetabular and femoral bone, were collected during 67 consecutive primary total hip arthroplasties in 67 patients. Broach samples were taken at the start and end of every reaming procedure. Four hundred two samples were taken, of which 26 were found to be positive for microorganisms. In 20 patients, at least one of these positive samples had been in direct contact with the actual prosthesis site, indicating that at least 30% of the involved patients had a possible bacterial contamination when leaving the operating theater.

Level Of Evidence: Diagnostic study, Level I-1 (testing of previously developed diagnostic criteria in series of consecutive patients--with universally applied reference gold standard). See the Guidelines for Authors for a complete description of levels of evidence.

Download full-text PDF

Source
http://dx.doi.org/10.1097/01.blo.0000149997.14631.0cDOI Listing

Publication Analysis

Top Keywords

total hip
12
perioperative contamination
8
primary total
8
hip arthroplasty
8
bacterial contamination
8
procedure samples
8
contamination
5
samples
5
contamination primary
4
arthroplasty unlabelled
4

Similar Publications

Background: Many studies have examined the prevalence of acetabular version (AV) and femoral version (FV) abnormalities and their effect on patient-reported outcomes (PROs) after hip arthroscopy for femoroacetabular impingement syndrome (FAIS), but few have explored the prevalence and influence of combined version (CV) abnormalities.

Purpose: To (1) describe the distribution of AV, FV, and CV in the largest cohort to date and (2) determine the relationship between AV, FV, and CV and PROs after hip arthroscopy for FAIS.

Study Design: Cohort study; Level of evidence, 3.

View Article and Find Full Text PDF

Purpose: To identify the PASS and SCB thresholds for hip arthroscopy and provide guidance on how to choose among the thresholds.

Methods: A systematic review of literature was conducted in PubMed and MEDLINE databases in August 2024 using the Preferred Reporting Items for Systematic Reviews and Meta-analyses guidelines. Studies with Level I to IV evidence that defined SCB or PASS thresholds for PROs for hip arthroscopy in the setting of intra-articular pathology were included.

View Article and Find Full Text PDF

Purpose: To identify sex-based differences in pathology, outcomes, and complications after hip arthroscopy for femoroacetabular impingement (FAI), and to compare patient-reported outcomes (PRO) scores between males and females.

Methods: The PubMed and MEDLINE databases were searched in September 2024, according to Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines. Included studies had data stratified by sex, minimum 2-year patient reported outcome (PRO) scores for hip arthroscopy in the setting of FAI and labral pathology, and a 2014 or later publication date.

View Article and Find Full Text PDF

Background: Postoperative cognitive dysfunction (POCD) is a postoperative complication of the central nervous system, especially in elderly patients. Growing evidence shows a close relationship between the kidney and cognition. This study aimed to evaluate the relationship between the subsequent risk of POCD and indicators related to the kidney.

View Article and Find Full Text PDF

Efficacy of small-diameter core decompression with platelet-rich plasma in early osteonecrosis of the femoral head: a retrospective study.

BMC Musculoskelet Disord

January 2025

Department of Orthopedics and Orthopedic Research Institute, West China Hospital, Sichuan University, Chengdu, People's Republic of China.

Background: Osteonecrosis of the femoral head (ONFH) is a challenging condition, primarily affecting young and middle-aged individuals, which results in hip dysfunction and, ultimately, femoral head collapse. However, the comparative effectiveness of joint-preserving procedures, particularly in the early stages of ONFH (ARCO stage I or II), remains inconclusive. This study aims to evaluate the efficacy of a novel technique called small-diameter core decompression (CD) combined with platelet-rich plasma (PRP), for the treatment of early-stage ONFH.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!