Traditionally, unilateral NMR systems such as the NMR-MOUSE have used the fringe field between two bar magnets joined with a yoke in a 'U' geometry. This allows NMR signals to be acquired from a sensitive volume displaced from the magnets, permitting large samples to be investigated. The drawback of this approach is that the static field (B0) generated in this configuration is inhomogeneous, and has a large, nonlinear, gradient. As a consequence, the sensitive volume of the instrument is both small and ill defined. Empirical redesign of the permanent magnet array producing the B0 field has yielded instruments with magnetic field topologies acceptable for varying applications. The drawback of current approaches is the lack of formalism in the control of B0. Rather than tailoring the magnet geometry to NMR investigations, measurements must be tailored to the available magnet geometry. In this work, we present a design procedure whereby the size, shape, field strength, homogeneity, and gradients in the sensitive spot of a unilateral NMR sensor can be controlled. Our design uses high permeability pole pieces, shaped according to the contours of an analytical expression, to control B0, allowing unilateral NMR instruments to be designed to generate a controlled static field topology. We discuss the approach in the context of previously published design techniques, and explain the advantages inherent in our strategy as compared to other optimization methods. We detail the design, simulation, and construction of a unilateral magnet array using our approach. It is shown that the fabricated array exhibits a B0 topology consistent with the design. The utility of the design is demonstrated in a sample nondestructive testing application. Our design methodology is general, and defines a class of unilateral permanent magnet arrays in which the strength and shape of B0 within the sensitive volume can be controlled.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.jmr.2005.01.009 | DOI Listing |
Mov Disord
January 2025
Department of Clinical Neurosciences, Parkinson and Movement Disorders Unit, Fondazione IRCCS Istituto Neurologico Carlo Besta, Milan, Italy.
Background: Magnetic resonance-guided focused ultrasound (MRgFUS) thalamotomy of ventral intermediate (Vim) nucleus is useful to treat drug-resistant tremor-dominant Parkinson's disease (TdPD), but tremor relapse may occur. Predictors of relapse have been poorly investigated so far.
Objective: The aim of this study is to evaluate the role of clinico-demographic, procedural, and neuroradiological variables in determining clinical response, relapse, and adverse events (AEs) in TdPD after MRgFUS Vim-thalamotomy.
J Med Case Rep
January 2025
School of Medicine, Isfahan University of Medical Sciences, Isfahan, Iran.
Background: Headaches are more prevalent in patients with multiple sclerosis compared with the general population. However, headaches are still considered a rare symptom of multiple sclerosis, especially when they appear as an initial symptom. The occurrence of a headache as a symptom of radiologically isolated syndrome (RIS) is uncommon, and it can significantly increase the likelihood of developing multiple sclerosis.
View Article and Find Full Text PDFAm J Ophthalmol Case Rep
December 2024
California Pacific Medical Center Department of Ophthalmology, 711 Van Ness, Suite 250, San Francisco, CA, 94102, USA.
Purpose: To report the case of a woman in her fifties whose presenting symptom of idiopathic intracranial hypertension was engorgement of the eyelid veins.
Observations: Bilateral engorged palpebral veins were visible through the skin. Dilated fundus examination revealed bilateral optic disc edema.
J Am Heart Assoc
January 2025
Department of Neurosurgery, Center of Pituitary Tumor, Ruijin Hospital Shanghai Jiao Tong University School of Medicine Shanghai China.
Background: Carotid endarterectomy (CEA) is widely used to treat carotid artery stenosis (CAS). However, the effects of CEA on unilateral CAS-induced cognitive impairment and the underlying mechanism remain poorly understood.
Methods And Results: Thirteen patients diagnosed with unilateral severe CAS underwent pre- and post-CEA assessments, including fluoro-2-deoxy-d-glucose positron emission tomography/magnetic resonance imaging, cognitive assessments, and routine blood tests before and after CEA.
J Bone Joint Surg Am
January 2025
Department of Bone and Joint Surgery, Renji Hospital, School of Medicine, Shanghai Jiaotong University, Shanghai, People's Republic of China.
Background: Early knee effusion is a common phenomenon after total knee arthroplasty (TKA), with potential clinical implications. Unlike traditional alloy knee prostheses, the polyetheretherketone (PEEK) knee system has radiographic transparency on magnetic resonance (MR) scans, which allows analysis of prosthetic knee effusion. We aimed to identify the distribution and volume of knee effusion after TKA with the PEEK prosthesis with use of MR imaging and to analyze whether dynamic changes in effusion were correlated with serum inflammatory marker changes and knee function recovery.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!