AI Article Synopsis

Article Abstract

Clinical management of carotid disease is primarily based on results of national trials (ACAS and NASCET) that used the distal internal carotid artery diameter as a reference. However, commonly accepted ultrasound (US) criteria for carotid stenosis were derived from the correlation of velocity measurements with angiographic bulb diameter reductions (BDR). This study was undertaken to compare the degree of carotid stenosis determined by conventional velocity criteria to the degree of stenosis measured by B-mode (gray scale) diameter at both the carotid bulb and at the distal internal carotid artery, and, second, to evaluate US imaging to derive distal diameter reductions (DDR) noninvasively. During a 3-month period patients referred for carotid US were prospectively analyzed for standard velocity criteria and plaque morphology. Minimum carotid diameter was measured by longitudinal and transverse B-mode measurements and compared to carotid bulb diameter and internal carotid diameter distal to all disease. B-mode diameter reductions were compared to the degree of stenosis determined by velocity criteria and to patient symptoms and the decision for carotid endarterectomy. In total, 131 carotid arteries in 74 patients were evaluated. Based on the University of Washington velocity criteria, lesions were classified as grade I (n = 61, 46%), IIA (n = 58, 44%), IIB (n = 7, 5%), or III (n = 5, 4%). BDR measured by B-mode predicted the grade of disease based on velocity criteria (p < 0.001) with an overall accuracy of 95%. With use of the B-mode for DDR (NASCET style), 18 patients exceeded the 60% threshold for surgical intervention. Of these, only 3 patients were symptomatic and were operated on. An additional 3 operated-on patients had an asymptomatic grade III stenosis, our usual threshold for intervention. Twelve additional patients were appropriate for surgical intervention by B-mode but were not treated based on conventional velocity criteria alone. Bulb diameter reduction by B-mode imaging correlates strongly with diameter reduction determined by velocity criteria, and independently predicts the grade of carotid disease. With this in mind, the accuracy of B-mode imaging may be extended to the measurement of carotid stenosis based on DDR. By B-mode criteria, many patients appropriate for intervention were not offered treatment based on conventional velocity criteria. Modern B-mode imaging provides a noninvasive method to obtain 'arteriographic equivalent'' measurements and should be added as a routine to carotid ultrasound interrogation.

Download full-text PDF

Source
http://dx.doi.org/10.1177/153857440503900203DOI Listing

Publication Analysis

Top Keywords

velocity criteria
32
carotid
15
internal carotid
12
carotid stenosis
12
bulb diameter
12
diameter reductions
12
conventional velocity
12
b-mode imaging
12
diameter
10
criteria
10

Similar Publications

Introduction: To examine the longitudinal association between estimated pulse wave velocity (ePWV) and cognitive phenotypes in a rural Chinese older population.

Methods: This population-based study included 1857 dementia-free participants (age ≥60 years) who were examined in 2014 and followed in 2018. ePWV was calculated using age and mean blood pressure (MBP).

View Article and Find Full Text PDF

Background: Advanced critical care echocardiography comprises a specific set of qualitative and quantitative point-of-care echocardiography skills, including a reliable, noninvasive method to measure cardiac output. This technique requires echocardiographic measurement of left ventricular outflow tract (LVOT) diameter and LVOT velocity time integral (VTI). Although there is a demand among critical care fellows to learn these advanced techniques, there are no data describing the acquisition of mastery in these skills.

View Article and Find Full Text PDF

Red blood cell distribution width (RDW) has recently been recognized as a novel biomarker associated with various cardiovascular conditions. This study aims to investigate the relationship between RDW and carotid-femoral pulse wave velocity (cfPWV) in a southern Chinese population. A total of 4916 patients were initially enrolled from the First Affiliated Hospital of Fujian Medical University between January 2016 and December 2022.

View Article and Find Full Text PDF

Objectives: To produce standards of references for quality control and assess the reproducibility of fetal ultrasound Doppler measurements commonly used for blood flow assessment in fetal growth.

Methods: Women with singleton normal pregnancies were prospectively recruited at University College London Hospital, UK, between 24 and 41 weeks. Umbilical artery (UA), middle cerebral artery (MCA), and their pulsatility indices (PI), resistance indices (RI) and ratios such as cerebro-placental (CPR) and umbilical cerebral ratio (UCR) were obtained twice by two sonographers in training or after completion of training, blind to each other's measurements.

View Article and Find Full Text PDF

Longitudinal assessment of retinal and visual pathway electrophysiology and structure after high altitude exposure.

Graefes Arch Clin Exp Ophthalmol

January 2025

Institute of Brain Diseases and Cognition, School of Medicine, Xiamen University, Xiamen, 361102, Fujian, China.

High altitude (HA) exposure induces impairments in visual function. This study was designed to dynamically observe visual function after returning to lowland and elucidate the underlying mechanism by examining the structure and function of retina and visual pathway. Twenty-three subjects were recruited before (Test 1), and one week (Test 2) and three months (Test 3) after their return from HA (4300 m) where they resided for 30 days.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!