Background: Recently, an endoscopic technique was developed to harvest the radial artery (RA) via a 3-cm wrist incision in patients undergoing coronary artery bypass graft (CABG). The aim of this study was to evaluate our initial clinical experience with this technology.

Methods: Data were prospectively collected on 75 consecutive patients undergoing CABG with endoscopic RA harvest using the Ultra-Retractor (CardioVations, Somerville, NJ, USA) and the harmonic scalpel (Ethicon Endo-Surgery, Cincinnati, OH, USA).

Results: There were 66 men (88%) and 9 women (12%) with a mean age of 60 years (range, 31-77 years). Forty-eight (64%) of cases had non-elective surgery. Thirty-one (41%) of patients had diabetes. Sixty seven percent of the operations were performed on pump and 33% off pump. Average RA harvest time was 66 minutes (range, 25-120 minutes) with a significant learning curve (75 minutes for the first 20 cases and 63 minutes for the last 50 cases). Two (2.6 %) radial arteries were discarded, one because of extensive calcifications and the other because of damage to the conduit. No patients suffered death, perioperative myocardial infarction, or stroke. There was one reexploration of the forearm for a tunnel hematoma. Follow-up was achieved in 100% of patients and averaged 3.6 months (range, 0.5-13 months). Two patients died during the follow-up. There were no myocardial infarctions or reinterventions, with 96% of patients in functional class I /II. There were no motor deficits. There were no sensory deficits in the distribution of the lateral antebrachial cutaneous nerve, but transient mild dorsal thenar numbness or paresthesias were observed in 86% of patients. Cosmetic results were defined as good to excellent in 82% of patients.

Conclusions: Short-term results of endoscopic RA harvest are excellent. There is a significant learning curve. Longterm follow-up as well as structural and functional assessments of the conduit are indicated.

Download full-text PDF

Source
http://dx.doi.org/10.1532/HSF98.20041049DOI Listing

Publication Analysis

Top Keywords

radial artery
8
coronary artery
8
artery bypass
8
initial clinical
8
clinical experience
8
patients
8
patients undergoing
8
endoscopic harvest
8
learning curve
8
minutes cases
8

Similar Publications

Background: Vascular thymus transplantation has been explored in animal models but remains untested in humans. Current approaches to congenital athymia involve avascular transplantation of allogeneic thymic tissue, which may delay immune recovery. Building on animal studies, we propose revascularization of thymic tissue in a human model.

View Article and Find Full Text PDF

Background: This study aims to demonstrate the 3-dimensional pattern of the nutrient vessels of the triquetrum using micro-computed tomography and determine the safe region for screw applications to the bone.

Methods: Seven fresh frozen cadavers' ulnar and radial arteries were injected with Microfil MV-117. Triquetral bones were dissected and examined using micro-computed tomography.

View Article and Find Full Text PDF

Objective: Hypertension, a common chronic disease, often leads to serious complications. While conventional management relies on antihypertensive drugs, which can cause side effects and adherence issues, alternative treatments like herbal medicine are gaining attention. This study examines the efficacy and safety of modified Saengmaeksan, an East Asian herbal remedy, in treating hypertension.

View Article and Find Full Text PDF

Comparison of Influence of Office and 24-h Central Aortic Blood Pressure on Target Organ Damage in Hypertension.

J Clin Hypertens (Greenwich)

January 2025

Department of Geriatrics, Medical Center on Aging of Shanghai Ruijin Hospital, Shanghai Jiaotong University School of Medicine, Shanghai, China.

The aim of this study was to explore whether 24-h ambulatory central (aortic) blood pressure (BP) has an advantage over office central aortic BP in screening for hypertension-mediated target organ damage (HMOD). A total of 714 inpatients with primary hypertension and the presence of several cardiovascular risk factors or complications involving clinical HMOD were enrolled. Twenty-four hour central aortic BP was measured by means of a noninvasive automated oscillometric device (Mobil-O-Graph).

View Article and Find Full Text PDF

Aims: To test utility of diffusion MRI-derived indices in carotid endarterectomy (CEA), change of diffusion tensor imaging (DTI) metrics, cerebral white matter (WM) volumes were evaluated and predictors of overall mortality determined.

Methods: Prospectively enrolled participants had preoperative, immediate and late postoperative DTI after CEA. WM volumes, DTI metrics (fractional anisotropy, FA; axial, radial, mean diffusivities; AD, RD, MD, respectively) were calculated for the index/contralateral hemispheres at all time points.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!