Automated determination of ziprasidone by HPLC with column switching and spectrophotometric detection.

Ther Drug Monit

Department of Psychiatry, University of Mainz, Untere Zahlbacherstrasse 8, D-55131 Mainz, Germany.

Published: April 2005

An isocratic high-performance liquid chromatography (HPLC) method with column switching and ultraviolet (UV) detection is described for quantitative analysis of the new antipsychotic drug ziprasidone. After centrifugation of serum or plasma samples and addition of fluperlapine as internal standard, the samples were injected into the HPLC system. On-line sample clean-up was conducted on a column (10 x 4.0 mm ID) filled with silica C8 material (20-microm particle size) using 8% (vol/vol) acetonitrile in deionized water as eluent. Ziprasidone was eluted and separated on ODS Hypersil C18 material (5 microm; column size 250 x 4.6 mm ID) using acetonitrile-water-tetramethylethylendiamine (50:49.6:0.4, vol/vol/vol). The UV detector was set at 254 nm. Ziprasidone was separated within 20 minutes. The limit of quantification was 10 ng/mL. At therapeutic concentrations, the interassay reproducibility (coefficient of variation) of quality control samples was below 10%. The method was found to be robust and stable. More than 100 serum samples could be analyzed without changing the clean-up column and more than 300 samples using the same analytic column. Among multiple drugs tested for interference, only the tricyclic antidepressants trimipramine and clomipramine were found to exhibit retention times similar to that of ziprasidone. The method was applied to analyze ziprasidone concentrations in blood serum of 67 patients treated with 40 to 280 mg ziprasidone per day for at least 7 days (median 120 mg). The median steady-state serum concentration of ziprasidone was 76 ng/mL, and the 25th and 75th percentile were 43 to 131 ng/mL, respectively. Forty to 130 ng/mL may be considered the recommended target plasma concentration range. HPLC with column switching and UV detection as described here is suitable for therapeutic drug monitoring of ziprasidone.

Download full-text PDF

Source
http://dx.doi.org/10.1097/01.ftd.0000150879.36296.4dDOI Listing

Publication Analysis

Top Keywords

column switching
12
ziprasidone
9
hplc column
8
detection described
8
column
7
samples
5
automated determination
4
determination ziprasidone
4
hplc
4
ziprasidone hplc
4

Similar Publications

Two-point contact is one of the fundamental problems of wheel-rail contact in switch area. The contact state and the distribution of forces are complex and essential points in wheel-rail relationship. Given the problem that the current dynamic wheel-rail contact state is challenging to detect, a theory to detect the two-point contact state of the wheel-rail in switch area using a discrete gauge column was presented and proved in the finite element model.

View Article and Find Full Text PDF

Metabolomics analyses enable the examination and identification of endogenous biochemical reaction products, revealing information on the metabolic pathways and processes active within a living cell or organism. Determination of metabolic shifts can provide important information on a treatment or disease. Unlike other omics fields that typically have analytes of the same chemical class with common building blocks, those that fall under the nomenclature of metabolites encompass a wide array of different compounds with very diverse physiochemical properties.

View Article and Find Full Text PDF

TBAT-Catalyzed Dioxasilinane Formation from Beta-Hydroxy Ketones.

Tetrahedron

February 2025

Department of Chemistry, Western Washington University, Bellingham, WA 98225 (USA).

Beta-hydroxy ketones can be reduced using a sequence of ruthenium-catalyzed silyl etherification followed by tetrabutylammonium fluoride (TBAF) promoted intramolecular hydrosilylation. Switching from TBAF to tetrabutylammonium difluorotriphenylsilicate (TBAT), even without first forming the silyl ether, gave cyclic dioxasilinane products. These somewhat sensitive compounds could be isolated pure by column chromatography using florisil as the stationary phase.

View Article and Find Full Text PDF

Development and validation of an UPLC-MS/MS method with polarity switching for simultaneous determination of 14 antiepileptic drugs and 2 metabolites in human serum.

J Pharm Biomed Anal

March 2025

Jiangsu Key Laboratory of New Drug Research and Clinical Pharmacy, Xuzhou Medical University, Xuzhou 221004, China; Department of Pharmacy, Suining People's Hospital Affiliated to Xuzhou Medical University, Suining 221202, China; Department of Pharmaceutical Analysis, Xuzhou Medical University, Xuzhou 221204, China. Electronic address:

Currently, treatment with antiepileptic drugs (AEDs) is still the first choice for epileptic patients, while monitoring their blood concentrations is undoubtedly beneficial for minimizing their adverse side effects and optimizing their therapeutic effects. In this study, an ultra-high performance liquid chromatography coupled with tandem mass spectrometry with polarity switching was developed and validated for simultaneous determination of 14 AEDs and 2 active metabolites in human serum. Olanzapine was selected as the internal standard.

View Article and Find Full Text PDF

Discovery of quality markers of based on an absorption-based metabolite approach and rapid quantification using polarity-switching UPLC-QQQ-MS/MS.

Front Pharmacol

December 2024

Qinghai-Tibetan Plateau Ethnic Medicinal Resources Protection and Utilization Key Laboratory of National Ethnic Affairs Commission of the People's Republic of China, Southwest Minzu University, Chengdu, China.

Article Synopsis
  • Regel (MQ) is a traditional Chinese medicine used for over a thousand years, but its clinical application suffers from a lack of identifiable quality markers that can ensure safety and efficacy.
  • An innovative metabolite approach using advanced chromatography techniques was developed to identify and quantify the quality markers of MQ, allowing for a more effective analysis of its pharmacological properties.
  • The study identified 13 absorbed compounds and 30 metabolites, with 9 specific compounds correlating with hepatocyte protection and absorption being proposed as quality markers for MQ.
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!