Rats were exposed for 6 h per day in inhalation chambers to a 10 mg/m(3) concentration of metalworking fluid (MWF) contaminated with endotoxin at concentrations of 1813 (low dose) and 20,250 eu/m(3) (high dose) 5 days per week for 8 weeks. It was found that 94.7% of the MWF aerosol particles had diameters in the range of 0.42-4.6 microm, with geometric mean diameter of 1.56 microm. The body weight and pulmonary function parameters were measured every week during the 8 weeks of exposure, whereas bronchoalveolar lavage (BAL) fluid was prepared to measure the inflammatory markers and cytokines after the 8 weeks of exposure. There were no changes in body weight and respiratory function (tidal volume and respiratory frequency) during the 8 weeks of exposure to the MWF containing endotoxins, yet lung weight increased significantly (P < 0.05) in the rats exposed to the MWF both with and without endotoxins. The number of polymorphonuclear (PMN) cells in the BAL fluid increased significantly (P < 0.05) in the rats exposed to MWF with endotoxins, and the levels of cytokines such as IL-4, INF-gamma, IL-1beta, and TNF-alpha also were significantly increased (P < 0.05) compared to the control. The NOx production activity of the BAL cells increased significantly (P < 0.05) in the rats exposed to the MWF with and without endotoxins. Increases in lung weight, number of PMN cells, and levels of extracellular cytokines and NOx were all more significant in the rats exposed to the MWF with endotoxins rather than in those exposed to MWF without endotoxins. In spleen cell cultures, T-cell proliferation activity was decreased, yet cytokine levels (INF-gamma, IL-1beta, IL-4, and TNF-alpha) remained unchanged after repeated exposure to MWF with and without endotoxins. Although the levels of total IgG(1), IgG(2a), and IgE antibodies in the serum were not changed, the levels of endotoxin-specific antibodies, including IgG(2a) and IgE, were increased significantly (P < 0.05) in the rats exposed to endotoxins, but there was not a significant increase in endotoxin-specific IgG(1). When taken together, the results indicate that lung inflammatory responses can be induced without changing pulmonary function after repeated exposure to MWFs contaminated with endotoxins. In addition, endotoxin-specific IgG(2a) and IgE may be effective biomarkers for workers exposed to MWFs contaminated with endotoxins in the workplace.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1002/tox.20097 | DOI Listing |
Microorganisms
January 2024
Department of Environmental and Public Health Sciences, Division of Environmental Genetics and Molecular Toxicology, University of Cincinnati College of Medicine, Cincinnati, OH 45267-0056, USA.
Microorganisms colonizing modern water-based metalworking fluids (MWFs) have been implicated in various occupational respiratory health hazards to machinists. An understanding of the exposure risks from specific microbial groups/genera/species (pathogenic or allergenic) and their endotoxins and the need for strategies for effective, timely fluid management warrant real-time extended tracking of the establishment of microbial diversity and the prevailing fluid-related factors. In the current study, the microbial community composition, succession, and dynamics of a freshly recharged industrial semi-synthetic MWF operation was tracked in real-time over a period of 50 weeks, using a combination of microbiological and molecular approaches.
View Article and Find Full Text PDFEnviron Res
January 2023
National Research Centre for the Working Environment, Lersø Parkallé 105, 2100, Copenhagen, Denmark. Electronic address:
Pigeon breeding is associated with exposure to airborne microorganisms and endotoxin and with symptoms of the airways. Antibiotic resistance is a threat to human health. Some pigeons participate in national and international indoor exhibitions.
View Article and Find Full Text PDFAnn Work Expo Health
February 2022
Department of Infectious Diseases/Clinical Bacteriology, University of Göteborg, Guldhedsgatan 10, 413 46 Göteborg, Sweden.
Objectives: The aim of this study was to characterize personal occupational exposure to endotoxin in size-separated airborne particles of MWF aerosol, using a Sioutas cascade impactor (SCI).
Methods: Exposure to inhalable fractions of MWF aerosol and endotoxin was measured by personal sampling of 52 individuals over an 8-h work shift using a PAS-6 sampler in parallel with a SCI (<0.25, 0.
Am J Ind Med
November 2021
Office of Occupational Medicine and Nursing, Directorate of Technical Support and Emergency Management, Occupational Safety and Health Administration, Washington, District of Columbia, USA.
Background: Workers exposed to metalworking fluids (MWF) can develop respiratory illnesses including hypersensitivity pneumonitis (HP). These respiratory manifestations are likely due to microbial contamination of aerosolized MWF. This paper reports a cluster of HP and respiratory symptoms at a manufacturing plant where MWF and workplace air were contaminated with bacterial endotoxin despite frequent negative bacterial cultures of MWF.
View Article and Find Full Text PDFWaste Manag
July 2021
National Research Centre for the Working Environment, Lersø Parkallé 105, 2100 Copenhagen Ø, Denmark. Electronic address:
Occupational exposure to microorganisms can be associated with adverse health outcomes. In this study, we assessed exposure to bioaerosols in two biowaste pretreatment plants in Denmark, which differed in location (city or countryside) and how they were built ('closed-off processes' or 'open processes'). Bioaerosol exposures were characterized by microbial concentrations in personal, stationary, sedimented dust, and hand samples, and their size distribution was assessed.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!