A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Quantitative angiographic analysis of right ventricular global function in normal incidences and in patients with coronary artery disease. | LitMetric

At present right ventriculography data cannot be accurately estimated owing to the absence of software for quantitative analysis of the right ventricle (RV) volumes and function. The aim of this study was to use existing software for left ventriculography analysis to estimate right ventricular volumes and function in patients without coronary lesions and in those with coronary artery disease (CAD). Thirty-two patients without significant lesions of coronary arteries and 20 patients with CAD were examined with left ventriculography and right atriography. Each examination was performed in 2 projections: 30 degrees right anterior oblique (RAO 30 degrees) and 60 degrees left anterior oblique (LAO 60 degrees) projections. Correction factor (CF) was obtained by finding the ratio between stroke volumes of the left and right ventricles. The mean CF was 0.9243+/-0.2887 for patients without CAD and 0.8758+/-0.2232 for patients with CAD. Such calculation is the easiest and quite accurate method of determining RV volumes and function by using existing software of quantitative angiographic analysis.

Download full-text PDF

Source
http://dx.doi.org/10.1177/000331970505600203DOI Listing

Publication Analysis

Top Keywords

volumes function
12
patients cad
12
quantitative angiographic
8
angiographic analysis
8
patients coronary
8
coronary artery
8
artery disease
8
software quantitative
8
existing software
8
left ventriculography
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!