The purpose of this study was to investigate whether the mechanical properties of the Achilles tendon were correlated to muscle strength in the triceps surae in humans. Twenty-four men and twelve women exerted maximal voluntary isometric plantar flexion (MVIP) torque. The elongation (DeltaX) and strain of the Achilles tendon (epsilon), the proximal part of which is the composite of the gastrocnemius tendon and the soleus aponeurosis, at MVIP were determined from the displacement of the distal myotendinous junction of the medial gastrocnemius using ultrasonography. The Achilles tendon force at MVIP (F) was calculated from the MVIP torque and the Achilles tendon moment arm. There were no significant differences in either the F-DeltaX or F-epsilon relationships between men and women. DeltaX and epsilon were 9.8 +/- 2.6 mm and 5.3 +/- 1.6%, respectively, and were positively correlated to F (r = 0.39, P < 0.05; r = 0.39, P < 0.05), which meant that subjects with greater muscle strength could store more elastic energy in the tendon. The regression y-intercepts for the F-DeltaX (P < 0.01) and F-epsilon (P < 0.05) relationship were significantly positive. These results might indicate that the Achilles tendon was stiffer in subjects with greater muscle strength, which may play a role in reducing the probability of tendon strain injuries. It was suggested that the Achilles tendon of subjects with greater muscle strength did not impair the potential for storing elastic energy in tendons and may be able to deliver the greater force supplied from a stronger muscle more efficiently. Furthermore, the difference in the Achilles tendon mechanical properties between men and women seemed to be correlated to the difference in muscle strength rather than gender.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1152/japplphysiol.00624.2004 | DOI Listing |
Cureus
November 2024
Physical Medicine and Rehabilitation, St. John's National Academy of Health Sciences, Bengaluru, IND.
Emery-Dreifuss Muscular Dystrophy (EDMD) is a rare genetic disorder characterized by muscle weakness, joint contractures, and cardiac dysfunction. Within this spectrum, EDMD Type 2, attributed to a heterozygous missense variant in exon 9 of the LMNA gene, presents a distinctive clinical profile. This case report details the presentation and management of a teenage girl displaying neck, trunk, upper and lower limb weakness, Achilles tendon contracture, and lordosis.
View Article and Find Full Text PDFBMC Musculoskelet Disord
December 2024
Department of Orthopedics, The First Hospital of Qinhuangdao, Qinhuangdao, China.
Objective: To provide clinicians with reliable recommendations for the selection of appropriate suturing techniques for surgical management of common musculoskeletal soft tissue injuries.
Methods: A systematic search of PubMed, Springer, Web Science, Vip Database, China National Knowledge, and Wanfang Data for in vitro biomechanical studies on suture techniques in the surgical treatment of musculoskeletal soft tissue injuries covering relevant studies from April 2009 to April 2024 was performed. A generalized classification was made based on the characteristics of the techniques, and recommendations for the selection of suture techniques were made according to the GRADE concept.
The plantaris muscle is spindle-shaped in the posterior compartment of the leg. It is distinguished for its small muscle belly and an exceptionally long tendon. It presents with great variability in its origin and insertion when present.
View Article and Find Full Text PDFJ Orthop Res
December 2024
McKay Orthopaedic Laboratory, University of Pennsylvania, Philadelphia, Pennsylvania, USA.
Exercise influences clinical Achilles tendon health in humans, but animal models of exercise-related Achilles tendon changes are lacking. Moreover, previous investigations of the effects of treadmill running exercise on rat Achilles tendon demonstrate variable outcomes. Our objective was to assess the functional, structural, cellular, and biomechanical impacts of treadmill running exercise on rat Achilles tendon with sensitive in and ex vivo approaches.
View Article and Find Full Text PDFJ Nanobiotechnology
December 2024
State Key Laboratory of Organic-Inorganic Composites, Beijing Laboratory of Biomedical Materials, Beijing University of Chemical Technology, Beijing, 100029, China.
Background: Electrospun nanofiber scaffolds have been widely used in tissue engineering because they can mimic extracellular matrix-like structures and offer advantages including high porosity, large specific surface area, and customizable structure. In this study, we prepared scaffolds composed of aligned and random electrospun polycaprolactone (PCL) nanofibers capable of delivering basic fibroblast growth factor (bFGF) in a sustained manner for repairing damaged tendons.
Results: Aligned and random PCL fiber scaffolds containing bFGF-loaded bovine serum albumin (BSA) nanoparticles (BSA-bFGF NPs, diameter 146 ± 32 nm) were fabricated, respectively.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!