Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1373/clinchem.2004.046607 | DOI Listing |
Prog Transplant
January 2025
Department of Surgery, Rush University Medical Center, University Transplant Program, Chicago, IL, USA.
Introduction: There is a need for a noninvasive, affordable, sensitive, and specific biomarker to diagnose early acute rejection, to negate the need for frequent biopsies. Dd-cfDNA is a powerful adjunct yet there is limited data on the ethnic differences in its values. There is anecdotal evidence that dd-cfDNA values at rejection may be higher in Black as compared to non-Black recipients.
View Article and Find Full Text PDFCureus
December 2024
Internal Medicine, Guthrie Lourdes Hospital, Binghamton, USA.
Splenic infarction with infectious mononucleosis (IM) caused by Epstein-Barr Virus (EBV) has been reported as a rare complication of IM. The monospot test, often used to diagnose EBV-related IM, may produce false-negative results, especially in atypical presentations or early stages of infection. This report describes the case of a monospot-negative patient who developed splenic infarction as a complication of IM.
View Article and Find Full Text PDFChin Med J Pulm Crit Care Med
December 2024
Department of Thoracic Surgery, Shanghai Pulmonary Hospital, School of Medicine, Tongji University, Shanghai 200433, China.
Immune checkpoint inhibitors (ICIs) have transformed the treatment landscape for resectable non-small cell lung cancer. Numerous trials have explored the use of ICIs, either as monotherapy or in combination with other therapies, in the neoadjuvant setting for stage I-III non-small cell lung cancer. Most trials have demonstrated neoadjuvant immunotherapy to be safe and to have remarkable efficacy, with a high pathological response rate and significantly improved event-free survival.
View Article and Find Full Text PDFAnal Chem
January 2025
Department of Chemical Engineering, University of Massachusetts Amherst, Amherst, Massachusetts 01003, United States.
Currently commercial colorimetric paper lateral flow immunoassays exhibit insufficient limit of detection (LOD) and limited clinical sensitivity toward the detection of SARS-CoV-2 antigens, which causes a high false negative rate. To mitigate this issue, a new plasmon-enhanced fluorescence probe was developed for paper lateral flow strips (PLFSs). The probe is made of a sandwich-structured Ag-core@silica@dye@silica-shell nanoparticle in which fluorescent dyes are sandwiched between the plasmonic Ag core and the silica outer shell, and the separation distance between the Ag core and the dye molecules is controlled by the silica space layer.
View Article and Find Full Text PDFMalar J
January 2025
Aklilu Lemma Institute of Pathobiology, Addis Ababa University, Addis Ababa, Ethiopia.
Background: Low malaria parasitaemia is a diagnostic challenge in pregnancy, leading to false negative microscopy and rapid diagnostic test (RDT) results. However, these submicroscopic or subpatent infections could cause adverse pregnancy outcomes. Thus, evaluating the diagnostic performance of microscopy, RDT, and multiplex qPCR in pregnancy is vital for informed decisions.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!