Colour-flow and pulsed-wave spectral Doppler echocardiography was performed on 6 healthy, adult Hispaniolan amazon parrots (Amazona ventralis) and 6 blue-fronted amazon parrots (Amazona a. aestiva) to establish normal reference values. Birds were anesthetized with isoflurane in oxygen and placed in dorsal recumbency. An electrocardiogram was recorded continuously and birds were imaged with a micro-phased-array scanner with a frequency of 7.0 MHz. After assessment of cardiac function in 2-D-echocardiography, blood flow across the left and the right atrioventricular valve and across the aortic valve was determined using color-flow and pulsed-wave spectral Doppler echocardiography. Diastolic inflow (mean value +/- standard deviation) into the left ventricle was 0.17 +/- 0.02 m/s (Hispaniolan amazons) and 0.18 +/- 0.03 m/s (Blue fronted amazons). Diastolic inflow into the right ventricle was 0.22 +/- 0.05 m/s (Hispaniolan amazons) and 0.22 +/- 0.04 m/s (Blue fronted amazons). Velocity across the aortic valve was 0.84 +/- 0.07 m/s (Hispaniolan amazons) and 0.83 +/- 0.08 m/s (Blue fronted amazons). Systolic pulmonary flow could not be detected in any of the birds in this study. No significant differences were evident between the two species examined. Results of this study indicate that Doppler echocardiography is a promising technique to determine blood flow in the avian heart. Further studies in other avian species are needed to establish reference values for assessment of cardiac function in diseased birds.
Download full-text PDF |
Source |
---|
J Clin Med
October 2024
Department of Obstetrics, Perinatology and Neonatology, Center of Postgraduate Medical Education, Cegłowska St. 80, 01-809 Warsaw, Poland.
This review aims to investigate the clinical implications of using the myocardial performance index (MPI), obtained through tissue Doppler imaging (TDI) and spectral Doppler, in assessing fetal cardiac function in growth-restricted fetuses. It explores the MPI's potential in predicting adverse perinatal outcomes and its utility when combined with conventional pulsed-wave Doppler assessments for enhanced fetal well-being evaluations. A systematic search of PubMed and Google Scholar databases spanning from 2004 to 2023 was conducted to identify pertinent articles on the MPI's clinical application in managing growth-restricted fetuses.
View Article and Find Full Text PDFSensors (Basel)
October 2024
Department of Industrial, Electronic and Mechanical Engineering, University of Roma Tre, 00146 Rome, Italy.
Quality assessment of ultrasound medical systems is a demanding task due to the high number of parameters to quantify their performance: in the present study, a Kiviat diagram-based integrated approach was proposed to effectively combine the contribution of some experimental parameters and quantify the overall performance of pulsed wave Doppler (PWD) systems for clinical applications. Four test parameters were defined and assessed through custom-written measurement methods based on image analysis, implemented in the MATLAB environment, and applied to spectral images of a flow phantom, i.e.
View Article and Find Full Text PDFJ Clin Med
August 2024
Division of Cardiology, The Mount Sinai Hospital, Icahn School of Medicine at Mount Sinai, New York, NY 10029, USA.
Clinical trials demonstrating improved cardiovascular outcomes with SGLT2 inhibitors have often had limited representation from Black and Hispanic populations. While the mechanisms of action are not well known, ethnicity- or gender-based receptor physiology may render SGLT2 inhibitors a better agent in certain populations over others. A medical records query yielded diabetic patients initiated on SGLT2 inhibitors between 2013 and 2020.
View Article and Find Full Text PDFVet Med Sci
September 2024
Department of Animal and Poultry Health and Nutrition, Faculty of Veterinary Medicine, University of Tehran, Tehran, Iran.
Background: Among the large animals, the heart of sheep is functionally and structurally very similar to the human heart. In research, sheep are used as an animal model to study the process of cardiac disease pathogenesis and treatment. Therefore, determining the normal values of the heart structures of sheep with echocardiography is of particular emphasis.
View Article and Find Full Text PDFAnimals (Basel)
May 2024
Department of Clinical Sciences, Faculty of Veterinary Medicine, University of Utrecht, 3584 CS Utrecht, The Netherlands.
In this multicenter, prospective, observational study, abdominal aortic flow was examined with pulsed-wave Doppler ultrasound in dogs with a left-to-right shunting patent ductus arteriosus (PDA) and in apparently healthy dogs. Forty-eight dogs with a PDA and 35 controls were included. In the dogs with a PDA, 37/48 had hemodynamically significant PDAs (hsPDAs) while 11/48 had non-hsPDAs, based on the presence or absence of echocardiographic signs of left-sided volume overload, respectively.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!