Molar mass distributions by gradient liquid chromatography: predicting and tailoring selectivity.

J Chromatogr A

Polymer-Analysis Group, Department of Chemical Engineering, University of Amsterdam, Nieuwe Achtergracht, 1018 WV Amsterdam, The Netherlands.

Published: February 2005

Interactive liquid chromatography (iLC) for polymer analysis is usually applied to the characterisation of distributions other than molar mass. In particular, its use for the determination of chemical-composition, functionality-type and tacticity distributions has been demonstrated. The application of iLC for the determination of molar mass distributions (MMDs), however, has not yet been fully explored. An expanded version of the reversed-phase liquid chromatography model has been developed to describe and predict how the retention behaviour of polydisperse polystyrene samples changes with molar mass. The relationship between molar mass and the parameters of the model has been investigated in some detail and non-linear correlations were found. From the model and the relationships between the model parameters and molar mass, calibration curves (retention time versus molar mass) were constructed to predict changes in chromatographic selectivity across a given molar mass range. These calibration curves were compared to experimentally obtained curves and, in most cases, excellent agreement was found. The dramatic enhancement in selectivity that can be obtained with iLC in comparison to size-exclusion chromatography (SEC) was illustrated by measuring matrix-assisted laser desorption ionisation (MALDI) MS spectra of fractions collected during a gradient-LC separation. In the low-molar mass range, essentially monodisperse fractions were obtained. Calibration curves, predicted by the model and validated experimentally using narrow-dispersity standards and MALDI-MS spectra of fractions, were used to determine the molar mass distribution of some narrowly distributed polystyrene samples. Molar mass distributions for such standards were found to be somewhat lower than the values reported by the manufacturers. The results also deviated from those obtained by MALDI-MS.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.chroma.2004.12.030DOI Listing

Publication Analysis

Top Keywords

molar mass
40
mass distributions
12
liquid chromatography
12
calibration curves
12
molar
10
mass
10
polystyrene samples
8
mass range
8
spectra fractions
8
distributions
5

Similar Publications

In this study, 34 deep eutectic solvents (DESs) were successfully prepared for the extraction of proanthocyanidin from Rhodiolae Crenulatae Radix et Rhizomes. The extraction process was optimized using single factor exploration and Box-Behnken design-response surface analysis. The extraction rate was significantly improved when the molar ratio of choline chloride to 1,3-propanediol was 1:3.

View Article and Find Full Text PDF

In this study, an acid-assisted extraction strategy was used to extract a novel polysaccharide (ACP) from after which this polysaccharide was purified and subjected to extensive characterization. ACP was determined to have an average molecular weight of 15,580 Da in structural characterization studies, and it was found to primarily consist of glucose, galactose, L-fucose, and fructose at an 82.14:12.

View Article and Find Full Text PDF

A case of enoxaparin-induced bullous hemorrhagic dermatosis is reported. A 69-year-old male with past medical history including chronic atrial fibrillation and a re-do aortic valve replacement, anticoagulated on warfarin, received an enoxaparin bridge for a molar extraction. On day 7 after restarting enoxaparin post-procedure at a therapeutic dose of 90 mg every 12 hours, the patient noticed multiple small, dark, raised lesions on his forearm and ankle.

View Article and Find Full Text PDF

Water-based green deep eutectic solvent: Application in liquid-liquid microextraction of trace bisphenol A in edible oils.

Talanta

December 2024

State Key Laboratory of Coal Conversion, Institute of Coal Chemistry, Chinese Academy of Sciences, Taiyuan, Shanxi, 030001, People's Republic of China. Electronic address:

In this study, tetrabutylammonium chloride (TBAC), tetrabutylammonium bromide (TBAB), and choline chloride (ChCl) were innovatively applied in the liquid-liquid microextraction (LLME) of bisphenol A (BPA) from edible oil by forming water-based deep eutectic solvent (WDES). The presence of water is not only used in the synthesis of WDES, but also modulates the viscosity of DES and improve its diffusion and mass transfer properties. Several crucial parameters affecting the extraction efficiency were examined, including the type and amount of WDES and the extraction time.

View Article and Find Full Text PDF

Size exclusion chromatography-gradient (SEC-Gradient) is a powerful technique to separate polymers by their chemical composition. The stationary phase is first conditioned with a gradient from adsorli to desorli, and polymer samples are injected after the gradient in SEC conditions. Since its first description in 2011 by Schollenberger and Radke, it has never been applied to block copolymers.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!