Introduction: Conventional retrograde nailing of the femur causes two important disadvantages: the proximal locking of the nail is difficult because of the anatomic conditions and a chondral defect was left into the knee.
Material And Methods: After the retrograde implantation the new nail was lead through the greater trochanter. An additional proximal aiming device for proximal interlocking can be fixed. The entrance portal will be sealed by an osteochondral cylinder. 50 cases of femur fractures were selected for the prospective study. We recorded all intraoperative complications and technical difficulties. The cases were followed up for 52 weeks, both clinical and radiology examinations were performed.
Results: The mean follow up was 15.5+/-5 months. All fractures were healed. Knee movement was 125+/-14 degrees. The Leung Score was 84+/-12.6 points; HSS Score was 90+/-9 points. In two cases wound infections were developed. Mal-union was observed in three cases, in two cases nail brake down.
Conclusions: The new retrograde interlocking nail could be used to manage femur fractures successfully. Two aiming devices enable a easy interlocking. Replacement of the osteochondral cylinder into the entry portal reduces cartilage damage.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s00113-004-0863-2 | DOI Listing |
Zhongguo Gu Shang
January 2025
Ningbo Beilun People's Hospital, Ningbo 315800, Zhejiang, China.
Objective: To investigate the effects of bone density, plate bending degree and proximal screw type on the stress fracture of clavicle hook.
Methods: Three sows weighing between 45 and 50 kg were selected, from which a total of 40 rivs were collected. The 15 ribs of sows were divided into 3 groups according to bone density and bone hardness with 5 rivs in each group.
Shoulder Elbow
January 2025
Department of Orthopaedic Surgery, Capio St Görans Hospital, Stockholm, Sweden.
Background: The aim of this study was to evaluate clinical results and complication rate in patients with proximal humeral fracture treated with Anatomical Locking Plate System (A.L.P.
View Article and Find Full Text PDFOrthop Traumatol Surg Res
January 2025
Ankara University Faculty of Medicine, Orthopaedics and Traumatology Department, Hand Surgery Unit, Ankara, Turkey.
Introduction: Although there is no consensus in the literature, it is believed that the Soong classification system and fracture pattern are risk factors for plate removal in distal radius fractures.
Hypothesis: The aim of this large-scale study was to evaluate the relationship between Soong classification, fracture pattern, and implant removal in distal radius fractures.
Materials And Methods: We retrospectively evaluated 795 patients who underwent surgery using a volar locking plate for distal radius fractures at our clinic between 2005 and 2022.
J Coll Physicians Surg Pak
January 2025
Department of Orthopaedics, Gansu Provincial Hospital, Lanzhou, China.
Null.
View Article and Find Full Text PDFJ Hand Surg Asian Pac Vol
January 2025
Mizoguchi Hospital, Fukuoka, Japan.
Synovial osteochondromatosis is a relatively rare condition of the hand. We present a rare case of a locked finger in a paediatric patient with synovial osteochondromatosis, in which a tumourous lesion was continuous with the flexor tendon and trapped proximal to the A1 pulley. After resection of the tumour and synovium, no recurrence was observed over a 6-month follow-up period.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!