Optimal bedside urinalysis for the detection of proteinuria in hypertensive pregnancy: a study of diagnostic accuracy.

BJOG

Reproductive Science Section, Department of Cancer Studies and Molecular Medicine, University of Leicester, Leicester Royal infirmary, Infirmary Square, Leicester LEI SWW, UK.

Published: April 2005

Objective: To compare semi-quantitative visual and automated methods of urine testing with fully quantitative point of care urinalysis for the detection of significant proteinuria (0.3 g/24 hours) in pregnancy complicated by hypertension.

Design: A prospective comparative study.

Setting: A large teaching maternity hospital.

Sample: One hundred and seventy-one pregnant women referred to the obstetric day-care unit for assessment of newly arisen hypertension.

Methods: Early morning urine specimens were tested with four dipstick techniques (Multistix 8SG visual and automated and microalbumin/creatinine ratio visual and automated; Bayer, Elkhart, USA) as well as a fully quantitative measure of the microalbumin creatinine ratio with the DCA 2000 (a point of care assay for albumin; Bayer). These results were compared to a 24-hour urine protein measurement and measures of diagnostic accuracy/prediction are reported.

Main Outcome Measures: Significant proteinuria (> or =0.3 g/24 hours) measured by laboratory assay.

Results: Automated dipstick urinalysis using the Clinitek 50 has significantly better predictive values for significant proteinuria (LR(+) 4.27, 95% CI 2.78 to 6.56; LR(-) 0.225, 95% CI 0.14 to 0.37) than conventional visual dipstick urinalysis (LR(+) 2.27, 95% CI 1.47 to 3.51; LR(-) 0.635, 95% CI 0.49 to 0.82). Dipstick microalbumin/creatinine ratio testing did not improve overall detection rates with automated or visual testing. Fully quantitative point of care measurement of albumin/creatinine ratio (ACR) was significantly better than any dipstick technique (LR(+) 14.6, 95% CI 6.74 to 31.8; LR(-) 0.069, 95% CI 0.030 to 0.16).

Conclusions: This study confirms that in pregnancy automated dipstick urinalysis is a more accurate screening test for the detection of proteinuria than visual testing. ACR testing can offer a significant improvement over conventional urinalysis if a fully quantitative method of detection is employed that uses pregnancy-specific thresholds. Dipstick assessment of ACR does not improve the detection rate of significant proteinuria.

Download full-text PDF

Source
http://dx.doi.org/10.1111/j.1471-0528.2004.00455.xDOI Listing

Publication Analysis

Top Keywords

fully quantitative
16
detection proteinuria
12
visual automated
12
point care
12
dipstick urinalysis
12
urinalysis detection
8
testing fully
8
quantitative point
8
g/24 hours
8
microalbumin/creatinine ratio
8

Similar Publications

Lineage tracing based on modern live imaging approaches enables to visualize, reconstruct, and analyze the developmental history, fate, and dynamic behaviors of cells in vivo in a direct, comprehensive, and quantitative manner. Light-sheet fluorescence microscopy (LSFM) has greatly boosted lineage tracing efforts, because fluorescently labeled specimens can be imaged in their entirety, over long periods of time, with high spatiotemporal resolution and minimal photodamage. In addition, an increasing arsenal of commercial and open-source software solutions for cell and nuclei segmentation and tracking can be employed to convert data from pixel-based to object-based representations, and to reconstruct the lineages of cells in their native context as they organize in tissues, organs, and whole organisms.

View Article and Find Full Text PDF

Association between brominated flame retardants and periodontitis: a large-scale population-based study.

Front Public Health

January 2025

The Affiliated Taizhou People's Hospital of Nanjing Medical University, Taizhou School of Clinical Medicine, Nanjing Medical University, Taizhou, China.

Background: The association between brominated flame retardants (BFRs) and periodontitis has remained unclear.

Methods: This research included adult participants from NHANES cycles 2009-2014. Survey-weighted generalized linear regressions were used to explore the associations between BFR exposure and periodontitis.

View Article and Find Full Text PDF

The segmentation of the retinogeniculate visual pathway (RGVP) enables quantitative analysis of its anatomical structure. Multimodal learning has exhibited considerable potential in segmenting the RGVP based on structural MRI (sMRI) and diffusion MRI (dMRI). However, the intricate nature of the skull base environment and the slender morphology of the RGVP pose challenges for existing methodologies to adequately leverage the complementary information from each modality.

View Article and Find Full Text PDF

Purpose: The aim of this study was to validate simplified methods for quantifying [Ga]Ga-FAPI-46 uptake against full pharmacokinetic modeling.

Methods: Ten patients with pancreatobiliary cancer underwent a 90-min dynamic PET/CT scan using a long axial field of view system. Arterial blood samples were used to establish calibrated plasma-input function from both continuous arterial sampling and image-derived input function (IDIF).

View Article and Find Full Text PDF

Mixed platoon with a human-driven leading vehicle may be a transition mode prior to the widespread adoption of fully autonomous platoon. Enhancing the driving safety of the leading vehicle driver is crucial for improving the overall operational safety of the mixed platoon. Predictive-Forward-Collision-Warning (PFCW), an emerging technology in transportation, holds promise in mitigating collision risks for drivers by presenting traffic information beyond their immediate visual range.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!