In this study, we investigated measurements of the intrinsic fluorescence of yeast hexokinase as an assay for glucose and immobilization of the enzyme in a silica sol-gel matrix as a potential in vivo glucose sensor for use in patients with diabetes. The intrinsic fluorescence of hexokinase in solution (excitation=295 nm, emission=330 nm) decreased by 23% at a saturating glucose concentration of 1 mM (Kd=0.3 mM), but serum abolished the glucose-related fluorescence response. When entrapped in tetramethylorthosilicate-derived sol gel, hexokinase retained activity, with a 25% maximal glucose-related decrease in intrinsic fluorescence, and the saturation point was increased to 50 mM glucose (Kd=12.5 mM). The glucose response range was increased further (to 120 mM, Kd=57 mM) by a covering membrane of poly(2-hydroxyethyl) methacrylate. Unlike free enzyme, the fluorescence responses to glucose with sol-gel immobilized hexokinase, with or without covering membrane, were similar for buffer and serum. We conclude that fluorescence monitoring of sol-gel entrapped yeast hexokinase is a suitable system for development as an in vivo glucose biosensor.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.ab.2005.01.016 | DOI Listing |
Small
January 2025
Leibniz-Institut für Polymerforschung e. V, Hohe Str. 6, 01069, Dresden, Germany.
Polyelectrolyte brushes (PEBs) undergo conformational transitions due to changes in pH and/or ionic strength, which is leveraged as smart surfaces and on-demand drug-release systems. However, probing conformational transitions of functional PEBs has remained challenging due to low spatiotemporal resolution of characterization methods. Herein, fluorescently-coupled PEBs are devised that give rise to Förster Resonance Energy Transfer (FRET) intrinsically coupled to conformational transitions of chains.
View Article and Find Full Text PDFJ Hazard Mater
January 2025
Key Laboratory of Physical Fitness and Exercise Rehabilitation of Hunan Province, Hunan Normal University, Changsha 410012, China. Electronic address:
Rare earth elements are integral to modern technology, but their increasing environmental distribution due to anthropogenic activities poses potential health risks to humans. This study utilized zebrafish as a model to assess developmental and locomotor performance effects of europium and samarium. Exposure to Eu or Sm induced a reduction in heart rate, growth inhibition, and morphological deformities.
View Article and Find Full Text PDFArthritis Rheumatol
January 2025
Department of Biology and Biotechnologies "Charles Darwin", Sapienza University of Rome, Rome, Italy.
Objective: A pathogenetic role of CD8+ T lymphocytes in radiographic axial spondyloarthritis (r-axSpA) and other spondyloarthritis (SpA) is sustained by genome-wide association studies (GWAS) and by the expansion of public T cell clonotypes in the target tissues. This study investigates the migration of CD8+ T cells, along with their phenotype and functions in patients with r-axSpA and psoriatic arthritis (PsA).
Methods: Peripheral blood CD8+ and CD4+ T cells were isolated from r-axSpA (n= 128), PsA (n= 60) and rheumatoid arthritis (RA, n= 74) patients and healthy donors (HD, n= 79).
Adv Compos Hybrid Mater
January 2025
J. Mike Walker '66 Department of Mechanical Engineering, Texas A&M University, College Station, TX 77843 USA.
Dosage tolerance is one of the translational challenges of using metformin (Met) in brain therapeutics. This paper presents metal-organic framework (MOF)-74-Mg nanocarriers (NCs) for intranasal (IN) delivery of brain-specific agents with a prolonged release time. We confirmed their excellent biocompatibility (5 mg/mL) and intrinsic fluorescence properties (370/500 nm excitation/emission peak) in Neuro-2A cells.
View Article and Find Full Text PDFAnal Chim Acta
February 2025
Shenzhen Key Laboratory of Synthetic Genomics, Guangdong Provincial Key Laboratory of Synthetic Genomics, CAS Key Laboratory of Quantitative Engineering Biology, Shenzhen Institute of Synthetic Biology, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, 518055, China. Electronic address:
Background: High-precision and broad-range pH detection is critical for health status assessment, such as signal transduction, enzyme activity, endocytosis, and cell proliferation and apoptosis. Although pH-responsive ratiometric fluorescent probes offer an effective pH monitoring strategy, their preparation often requires multi-step modification and decreases fluorescence efficiency and stability. Herein, we developed a simple method to prepare fluorescent Si dots with dual emission centers for high-precision and broad-range pH monitoring, and the detection of urease based on pH-responsive Si dots and pH monitoring in living cell was further explored.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!