Implant-supported fixed prosthesis is a treatment option to restore missing teeth. Occasionally, it is necessary to connect teeth and implants as abutments for these restorations. Whether such restorations can be recommended is a matter of debate. This in vivo study measured strains involved in connecting implants to a natural tooth and compared rigid and nonrigid tooth/implant connections. A patient was treated with mandibular unilateral fixed prosthesis supported by two implants and one proximal tooth. Strain gauges were cemented to the experimental framework restoration. Recordings were obtained from the restorations while the patient bit on a wooden stick on the day of placement and after 2 weeks in function, using both rigid and nonrigid attachment connections. A significant difference was found in horizontal deformation of the tooth/crown between day 1 and 2 weeks later. Vertical deformations were smaller than horizontal ones. After applying biting forces, horizontal and vertical deformations were maintained. Strain recorded in a clinical setting revealed mostly horizontal strains generated in a combined tooth/implant device. These strains were maintained after a 2-week recording. Within the limitation of this study, combined tooth/implant restorations could be a potential complication and could cause an intrusion of a natural abutment regardless of the type of connection (rigid or nonrigid).
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1097/01.id.0000154792.14103.94 | DOI Listing |
Int J Comput Assist Radiol Surg
December 2024
Research Center for Medical AI, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen, China.
Purpose: In laparoscopic liver surgery, registering preoperative CT-extracted 3D models with intraoperative laparoscopic video reconstructions of the liver surface can help surgeons predict critical liver anatomy. However, the registration process is challenged by non-rigid deformation of the organ due to intraoperative pneumoperitoneum pressure, partial visibility of the liver surface, and surface reconstruction noise.
Methods: First, we learn point-by-point descriptors and encode location information to alleviate the limitations of descriptors in location perception.
J Comput Chem
January 2025
Department of Chemistry and Biochemistry, University of Mississippi, Oxford, Mississippi, USA.
The difficulty of quantum chemically computing vibrational, rotational, and rovibrational reference data via quartic force fields (QFFs) for molecules containing aluminum appears to be alleviated herein using a hybrid approach based upon CCSD(T)-F12b/cc-pCVTZ further corrected for conventional CCSD(T) scalar relativity within the harmonic terms and simple CCSD(T)-F12b/cc-pVTZ for the cubic and quartic terms: the F12-TcCR+TZ QFF. Aluminum containing molecules are theorized to participate in significant chemical processes in both the Earth's upper atmosphere as well as within circumstellar and interstellar media. However, experimental data for the identification of these molecules are limited, showcasing the potential for quantum chemistry to contribute significant amounts of spectral reference data.
View Article and Find Full Text PDFJ Synchrotron Radiat
January 2025
Cardiovascular Resarch Group iCare4Kids, Institut de Recerca Sant Joan de Déu, Esplugues de Llobregat, Spain.
One of the main limitations of conventional absorption-based X-ray micro-computed tomography imaging of biological samples is the low inherent X-ray contrast of soft tissue. To overcome this limitation, the use of ethanol as contrast agent has been proposed to enhance image contrast of soft tissues through dehydration. Some authors have shown that ethanol shrinks and hardens the tissue too much, also causing small tissue ruptures due to fast dehydration.
View Article and Find Full Text PDFJ Clin Med
December 2024
Herston Biofabrication Institute, Metro North Health, Herston, QLD 4029, Australia.
: Prostate-specific membrane antigen positron emission tomography/computed tomography (PSMA PET/CT), in combination with magnetic resonance imaging (MRI), may enhance the diagnosis and staging of prostate cancer. Image fusion of separately acquired PET/CT and MRI images serve to facilitate clinical integration and treatment planning. This study aimed to investigate different PSMA PET/CT and MRI image fusion workflows for prostate cancer visualisation.
View Article and Find Full Text PDFDiagn Interv Imaging
December 2024
IHU LIRYC, Heart Rhythm Disease Institute, Université de Bordeaux, INSERM U1045, 33604, Pessac, France; Department of Diagnostic and Interventional Radiology, Lausanne University Hospital and University of Lausanne, 1011 Lausanne, Switzerland; Department of Cardiovascular Imaging, Hôpital Cardiologique du Haut-Lévêque, CHU de Bordeaux, 33604 Pessac, France. Electronic address:
Purpose: The purpose of this study was to introduce and evaluate a novel two-dimensional wideband black-blood (BB) LGE sequence, incorporating wideband inversion recovery, wideband T2 preparation, and non-rigid motion correction (MOCO) reconstruction, to improve myocardial scar detection and address artifacts associated with implantable cardioverter defibrillators (ICDs).
Materials And Methods: The wideband MOCO free-breathing BB-LGE sequence was tested on a sheep with ischemic scar and in 22 patients with cardiac disease, including 15 with cardiac implants, at 1.5 T.