Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Background And Purpose: Patients undergoing stent placement as treatment for severe stenosis of the internal carotid artery (ICA) were assessed with MR imaging in a combined MR-radiographic (XMR) angiography suite. MR imaging was performed before and immediately following conventional radiography-guided stent placement. Changes in MR imaging measurable properties, including flow and perfusion, resulting from stent placement were evaluated.
Patients And Techniques: MR imaging analysis was performed for 12 patients with >70% stenosis of the ICA before and after conventional radiography-guided deployment of a carotid stent. MR imaging acquisitions included angiography, quantitative flow analysis, perfusion, diffusion, and turbo-fluid-attenuated inversion recovery (FLAIR). These acquisitions were all performed immediately before and following stent placement by using conventional techniques.
Results: MR angiography proved sufficient for identifying the target lesion and permitting targeted flow analysis. MR flow analysis demonstrated a marked increase in flow in the treated carotid artery (+2.2 +/- 1.2 mL/s) and little change in other extracranial arteries. MR perfusion imaging showed no significant differences in relative cerebral blood volume between hemispheres before or after treatment, but there was a modest decrease in mean transit time and time to peak evident in the treated hemisphere after stent placement. Diffusion imaging did not demonstrate any ischemic foci resulting from carotid stent treatment. Hyperintensity of the CSF was noted on turbo-FLAIR acquisitions in the ipsilateral hemisphere following stent placement in 75% of patients.
Conclusion: MR imaging reliably reflects the state of the carotid artery and provides a means of monitoring and quantifying the effects of revascularization.