The structure of multiply hydrogen-bonded systems is determined with picometer accuracy by a combined solid-state NMR and quantum-chemical approach. On the experimental side, advanced 1H-15N dipolar recoupling NMR techniques are capable of providing proton-nitrogen distances of up to about 250 pm with an accuracy level of +/-1 pm for short distances (i.e., around 100 pm) and +/-5 pm for longer ones (i.e., 180 to 250 pm). The experiments were performed under fast magic-angle spinning, which ensures sufficient dipolar decoupling and spectral resolution of the 1H resonance lines. On the quantum-chemical side, the structures of the hydrogen-bonded systems were computationally optimised, yielding complete sets of nitrogen-proton and proton-proton distances, which are essential for correctly interpreting the experimental NMR data. In this way, nitrogen-proton distances were determined with picometer accuracy, so that vibrational averaging effects on dipole-dipole couplings need to be considered. The obtained structures were finally confirmed by the complete agreement of computed and experimental 'H and '5N chemical shifts. This demonstrates that solid-state NMR and quantum-chemical methods ideally complement each other and, in a combined manner, represent a powerful approach for reliable, high-precision structure determination whenever scattering techniques are inapplicable.

Download full-text PDF

Source
http://dx.doi.org/10.1002/cphc.200400338DOI Listing

Publication Analysis

Top Keywords

picometer accuracy
12
hydrogen-bonded systems
8
determined picometer
8
solid-state nmr
8
nmr quantum-chemical
8
nmr
5
determining geometry
4
geometry hydrogen
4
hydrogen bonds
4
bonds solids
4

Similar Publications

Infinitesimal optical singularity ruler for three-dimensional picometric metrology.

Nat Commun

December 2024

Nanophotonics Research Center, Institute of Microscale Optoelectronics, State Key Laboratory of Radio Frequency Heterogeneous Integration, Shenzhen University, Shenzhen, 51806, China.

Optical metrology with picometer-scale precision in three-dimensional space is of considerable importance in modern physics and state of the art technology, optical interference is an effective method, but techniques with rapid spatial variation have the potential to enhance measurement precision, which will be required as measurement dimensions decrease. Here, the concept of the vanishingly small optical phase singularity ruler is introduced. Inspired by the well-known plumb-line technique used to locate the centroid, an analogous singularity line technique is proposed to locate the optical singularity with a precision of ~4.

View Article and Find Full Text PDF

Polar vortex hidden in twisted bilayers of paraelectric SrTiO.

Nat Commun

December 2024

School of Materials Science and Engineering, Tsinghua University, Beijing, 100084, China.

Polar topologies, such as vortex and skyrmion, have attracted significant interest due to their unique physical properties and promising applications in high-density memory devices. To date, all known polar vortices are present in or induced by ferroelectric materials. In this study, we find polar vortex arrays in paraelectric SrTiO.

View Article and Find Full Text PDF

A phase demodulation algorithm based on an adaptive polar transform is proposed that can achieve picometer-scale measurements in orbital angular momentum (OAM) interferometry. The proposed algorithm converts the rotational movement in a petal-shaped interference pattern into translational movement of the grayscale projection curves, so that can be easily measured using correlation operations to determine the pixel displacement in determining the rotation angle. Displacements ranging from -120 nm to 120 nm have been measured for various topological charges, with a minimum average deviation of 0.

View Article and Find Full Text PDF

This paper discusses the generation of a novel periodic nonlinear error in homodyne interferometers due to geometric misalignments. These misalignments arise from cumulative assembly errors among the sensor head interior, target mirror, test platform, and detector, leading to dynamic misplacement of the measurement beam on the detector's surface. A physical model was developed to explain this error, focusing on the interference field produced by Gaussian beams under conditions of beam separation and inclined interference.

View Article and Find Full Text PDF

Bayesian inference of atomic column positions in scanning transmission electron microscopy images.

Microscopy (Oxf)

December 2024

Nanostructures Research Laboratory, Japan Fine Ceramics Center, 2-4-1 Mutsuno, Atsuta-ku, Nagoya, Aichi 456-8587, Japan.

Atomic-resolution scanning transmission electron microscopy combined with two-dimensional Gaussian fitting enables the accurate and precise identification of atomic column positions within a few picometers. The measurement performance significantly depends on the signal-to-noise ratio of the atomic columns. In areas with low signal-to-noise ratios, such as near surfaces, the measurement performance was lower than that of the bulk.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!