A total of 3,023 clinical specimens were tested for Neisseria gonorrhoeae by using COBAS AMPLICOR (CA) PCR and confirmation of positives by N. gonorrhoeae-specific 16S rRNA PCR. The sensitivity of CA plus 16S rRNA PCR was 98.8%, compared to 68.2% for culture. Confirmation of CA positives increased the positive predictive value from 54.8 to 96.6%.