A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Impact of setup uncertainty in the dosimetry of prostate and surrounding tissues in prostate cancer patients treated with Peacock/IMRT. | LitMetric

The purpose of this paper was to assess the effect of setup uncertainty on dosimetry of prostate, seminal vesicles, bladder, rectum, and colon in prostate cancer patients treated with Peacock intensity-modulated radiation therapy (IMRT). Ten patients underwent computed tomography (CT) scans using the "prostate box" for external, and an "endorectal balloon" for target immobilization devices, and treatment plans were generated (T1). A maximum of +/-5-mm setup error was chosen to model dosimetric effects. Isodose lines from the T1 treatment plan were then superimposed on each patient's CT anatomy shifted by 5 mm toward the cephalad and caudal direction, generating 2 more dosimetric plans (H1 and H2, respectively). Average mean doses ranged from 74.5 to 74.92 Gy for prostate and 73.65 to 74.94 Gy for seminal vesicles. Average percent target volume below 70 Gy increased significantly for seminal vesicles, from 0.53% to 6.26%, but minimally for prostate, from 2.08% to 4.4%. Dose statistics adhered to prescription limits for normal tissues. Setup uncertainty had minimum impact on target dose escalation and normal tissue dosing. The impact of target dose inhomogeneity is currently evaluated in clinical studies.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.meddos.2004.10.001DOI Listing

Publication Analysis

Top Keywords

setup uncertainty
12
seminal vesicles
12
uncertainty dosimetry
8
dosimetry prostate
8
prostate cancer
8
cancer patients
8
patients treated
8
impact target
8
target dose
8
prostate
6

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!