A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Clotting state after cardioversion of atrial fibrillation: a haemostasis index could detect the relationship with the arrhythmia duration. | LitMetric

BACKGROUND: Fibrin D-dimer levels have been advocated as an useful clinical marker of thrombogenesis. HYPOTHESIS: We hypothesized that i) there is a hyperclotting state after the return of atrial fibrillation to sinus rhythm, ii) the measurement of plasma D-Dimer levels might be a good screening tool of this clotting status, and iii) the duration of arrhythmia influences the haemostasis measured by plasma D-Dimer levels. METHODS: Forty-two patients with atrial fibrillation undergoing cardioversion were divided into two groups: in Group A (n = 24,14 male, 56 +/- 11 years) the duration of atrial fibrillation was 72 hours or more (142.7 +/- 103.8 hours), in Group B (n = 18, 10 male, 61 +/- 13 years) the duration of atrial fibrillation was less than 72 hours (25 +/- 16 hours). Plasma fibrin D-dimer levels were measured by enzyme immunoassay before, and 36 hours after, cardioversion. The change of plasma D-dimer levels 36 hours after cardioversion was calculated as delta-D-dimer. RESULTS: There were no significant differences in demographic, clinical, and echocardiographic data, and the success of cardioversion between the two groups. Compared to the control, the baseline D-dimer levels were significantly higher in both groups. The delta D-dimer levels were significantly higher in Group A than in Group B (p < 0.005). Furthermore, plasma D-dimer levels 36 hours after cardioversion (r = 0.52, p = 0.0016) and delta-D-dimer levels (r = 0.73, p < 0.0001) showed significant correlations with the duration of atrial fibrillation. CONCLUSION: The longer duration of the atrial fibrillation episode could lead to a more prominent cardiovascular hyperclotting state after cardioversion, and the mean changes of plasma D-Dimer levels could be used as an useful clinical marker of the clotting state after atrial systole return.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC555849PMC
http://dx.doi.org/10.1186/1477-9560-3-2DOI Listing

Publication Analysis

Top Keywords

d-dimer levels
36
atrial fibrillation
28
plasma d-dimer
20
duration atrial
16
hours cardioversion
12
levels
10
d-dimer
9
clotting state
8
state cardioversion
8
atrial
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!