A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Exercise-induced respiratory resistance changes as measured with the airflow perturbation device. | LitMetric

Exercise-induced respiratory resistance changes as measured with the airflow perturbation device.

Physiol Meas

Biological Resources Engineering, University of Maryland, College Park, MD 20742, USA.

Published: February 2005

Respiratory resistance (Rrs) changes during physical labor can modify the work of breathing and thus influence the time that the labor can be performed. Ideal in vivo human respiratory performance measurements should have fine temporal resolution and minimally impact the respiratory system itself. The airflow perturbation device (APD) provides respiratory resistance measurements in this manner. Pre-exercise Rrs was compared with post-exercise Rrs, continuously monitored for 6 min in 12 non-asthmatic subjects. Rrs following exercise at 70-75% VO2max was below pre-exercise levels for 40 s into recovery (p < 0.05) and inhalation resistance differed more markedly than exhalation resistance. The same post-exercise Rrs decline was found when Rrs measurements were compared to those taken during flow rates comparable to those found late in recovery. Results indicate that (1) Rrs indeed declines following exercise in non-asthmatic subjects, probably due to bronchial dilation, (2) Rrs changes can occur on short time scales, (3) Rrs changes are not related primarily to flow rate.

Download full-text PDF

Source
http://dx.doi.org/10.1088/0967-3334/26/1/003DOI Listing

Publication Analysis

Top Keywords

respiratory resistance
12
rrs changes
12
rrs
9
airflow perturbation
8
perturbation device
8
post-exercise rrs
8
non-asthmatic subjects
8
resistance
5
exercise-induced respiratory
4
changes
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!