In an effort to regulate the behavior of mammalian cell entrapped in a gel, the gels were functionalized with the putative cell-binding (-Arg-Gly-Asp-) (RGD) domain. The adhesion molecules composed of Gly-Arg-Gly-Asp-Ser (GRGDS) peptides and the cell recognition ligands were inculcated into the thermo-reversible hydrogel composed of N-isopropylacrylamide, with a small amount of succinyl poly(ethylene glycol) (PEG) acrylate (MW 2000) used as the biomimetic extracellular matrix (ECM). The GRGDS-containing p(NiPAAm-co-PEG) copolymer gel was examined in vitro for its ability to promote cell spreading and to increase the viability of the cells by introducing PEG spacers. ECM poorly adhered to hydrogel lacking adhesion molecules permitting only a 20% spread of the seeded cells after 10 days. When the PEG spacer arms, which were immobilized by a peptide linkage, had been integrated into the hydrogel, the conjugation of RGD improved cell spreading by 600% in a 10-day trial.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s10529-004-8297-zDOI Listing

Publication Analysis

Top Keywords

polyethylene glycol
8
thermo-reversible hydrogel
8
extracellular matrix
8
adhesion molecules
8
cell spreading
8
enhancement adhesion
4
adhesion fibroblasts
4
fibroblasts peptide
4
peptide arg-gly-asp
4
arg-gly-asp sequence
4

Similar Publications

Dust emissions from open-pit mining pose a significant threat to environmental safety and human health. Currently, the range of dust suppressants used in coal mining is limited, often failing to account for their suitability across various stockpiles. This oversight results in poor infiltration after application, leading to insufficient crust formation and reduced durability.

View Article and Find Full Text PDF

The [18F] F-PSMA Probe: Chemical Perspectives.

Curr Med Chem

January 2025

Brazilian Nuclear Energy Commission, Nuclear Engineering Institute, Laboratory of Novel Radiopharmaceuticals and Nanoradiopharmacy, Rio de Janeiro, 21941906, Brazil.

This study discusses the chemical perspectives of the [18F]F-PSMA probe, a pivotal tool in prostate cancer imaging. [18F]Fluorine, a positron emitter with a half-life of 109.8 minutes, is produced in a cyclotron by bombarding [18O]-enriched targets with protons.

View Article and Find Full Text PDF

Ganglioside-incorporating lipid nanoparticles as a polyethylene glycol-free mRNA delivery platform.

Biomater Sci

January 2025

Department of Bio and Brain Engineering, and KAIST Institute for Health Science and Technology, Korea Advanced Institute of Science and Technology (KAIST), Daejeon 34141, Republic of Korea.

Incorporation of polyethylene glycol (PEG) is widely used in lipid nanoparticle (LNP) formulation in order to achieve adequate stability due to its stealth properties. However, studies have detected the presence of anti-PEG neutralizing antibodies after PEGylated LNP treatment, which are associated with anaphylaxis, accelerated LNP clearance and premature release of cargo. Here, we report the development of LNPs incorporating ganglioside, a naturally occurring stealth lipid, as a PEG-free alternative.

View Article and Find Full Text PDF

Background: Spinal cord injury (SCI) treatment remains a formidable challenge, as current therapeutic approaches provide only marginal relief and fail to reverse the underlying tissue damage. This study aims to develop a novel composite material combining enzymatic nanoparticles and nerve growth factor (NGF) to modulate the immune microenvironment and enhance SCI repair.

Methods: CeMn nanoparticles (NP) and CeMn NP-polyethylene glycol (PEG) nanozymes were synthesized via sol-gel reaction and DSPE-mPEG modification.

View Article and Find Full Text PDF

Biomechanical comparison of the efficacy of Cfr-PEEK and titanium systems in the fixation following sagittal split advancement osteotomy: a biomechanical study.

BMC Oral Health

January 2025

Department of Oral and Maxillofacial Surgery, Ordu University, Cumhuriyet Yerleşkesi Cumhuriyet Mahallesi, 52200, Ordu, Türkiye, Turkey.

Background: This study evaluates the efficacy of carbon fiber reinforced Polyetheretherketone (Cfr-PEEK) in fixation after sagittal split ramus osteotomy (SSRO) by comparing it with titanium in vitro.

Methods: Twenty-eight sheep hemimandibles were randomly assigned to four groups for SSRO surgery. Fixation was performed with a 4-hole titanium mini plate for 5 mm advancement in Group 1, with a 4-hole Cfr-PEEK mini plate for 5 mm advancement for Group 2, with a 4-hole titanium mini plate for 10 mm advancement for Group 3, and with a 4-hole Cfr-PEEK mini plate for 10 mm advancement for Group 4.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!