BACKGROUND: Objective measures of hand function as individuals participate in home and community activities are needed in order to better plan and evaluate rehabilitation treatments. Traditional measures collected in the clinical setting are often not reflective of actual functional performance. Recent advances in technology, however, enable the development of a lightweight, comfortable data collection monitor to measure hand kinematics. METHODS: This paper presents the design analysis of a wearable sensor glove with a specific focus on the sensors selected to measure bend. The most important requirement for the glove is easy donning and removal for individuals with significantly reduced range of motion in the hands and fingers. Additional requirements include comfort and durability, cost effectiveness, and measurement repeatability. These requirements eliminate existing measurement gloves from consideration. Glove construction is introduced, and the sensor selection and glove evaluation process are presented. RESULTS: Evaluation of commercial bend sensors shows that although most are not appropriate for repeatable measurements of finger flexion, one has been successfully identified. A case study for sensor glove repeatability using the final glove configuration and sensors does show a high degree of repeatability in both the gripped and flat hand positions (average coefficient of variability = 2.96% and 0.10%, respectively). CONCLUSION: Measuring functional outcomes in a portable manner can provide a wealth of information important to clinicians for the evaluation and treatment of movement disorders in the hand and fingers. This device is an important step in that direction as both a research and an evaluation method.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC555583 | PMC |
http://dx.doi.org/10.1186/1743-0003-2-5 | DOI Listing |
Drug Alcohol Depend
January 2025
RAND, Boston, MA, United States. Electronic address:
Importance: States have implemented multiple policies likely to influence opioid prescribing; few national general population studies examine those policies' effects on per-capita opioid morphine milligram equivalents (MME) dispensed.
Objective: To examine state policies' effects on opioids per-capita MMEs dispensed at retail pharmacies.
Design: A longitudinal study of associations between MME per capita and implementation of policy interventions at different times across states.
J Hypertens
November 2024
Robert Koch Institute, Department of Epidemiology and Health Monitoring.
Objectives: Home blood pressure monitoring (HBPM) is valuable for the detection and monitoring of hypertension. Despite logistical advantages, HBPM has not yet been used in national blood pressure (BP) surveys. We investigated randomly selected adults' willingness to participate in an HBPM study (attitude survey) and piloted this approach (feasibility study).
View Article and Find Full Text PDFAm Fam Physician
January 2025
Duke University School of Medicine, Durham, N.C.
Gastroesophageal reflux is a common physiologic event in infants in which gastric contents pass from the stomach into the esophagus. Gastroesophageal reflux may be asymptomatic or cause regurgitation or "spit up." This occurs daily in approximately 40% of infants.
View Article and Find Full Text PDFPLoS One
January 2025
College of Engineering, South China Agricultural University, Guangzhou, China.
In order to address many issues, such as the inconsistent and unreliable seeding process in traditional mechanical garlic seed metering systems (SMS), as well as the lack of ability to monitor the effectiveness of the seeding, a highly accurate electric-driven metering system (EDMS) was developed and created specifically for garlic seed planters. This study provided a description of the overall structure and functioning principle, as well as an analysis of the mechanism for smooth transit and delivery. A combination of an infrared (IR) sensor, Arduino Mega board, stepper motor, speed sensor, and a Wi-Fi module was employed to operate the EDMS, as well as monitor and count the quantity of garlic seeds during the planting process and determine the qualified rate (QR) and missing rate (MR).
View Article and Find Full Text PDFPLoS One
January 2025
Department of Gastroenterology, Graduate School of Medicine, The University of Tokyo, Tokyo, Japan.
Objective: This study aimed to introduce and evaluate a novel software-based system, BioTrace, designed for real-time monitoring of thermal ablation tissue damage during image-guided radiofrequency ablation for hepatocellular carcinoma (HCC).
Methods: BioTrace utilizes a proprietary algorithm to analyze the temporo-spatial behavior of thermal gas bubble activity during ablation, as seen in conventional B-mode ultrasound imaging. Its predictive accuracy was assessed by comparing the ablation zones it predicted with those annotated by radiologists using contrast-enhanced computed tomography (CECT) 24 hours post-treatment, considered the gold standard.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!