Effect of increased diaphragm activation on diaphragm power spectrum center frequency.

Respir Physiol Neurobiol

Research Center, Respiratory Health Research Unit, Sacré-Coeur Hospital of Montréal, Montreal, Que., Canada H4J 1C5.

Published: March 2005

Increased transdiaphragmatic pressure, reduced muscle blood flow, and increased duty cycle have all been associated with a reduction in the center frequency (CFdi) of the diaphragm's electrical activity (EAdi). However, the specific influence of diaphragm activation on CFdi is unknown. We evaluated whether increased diaphragm activation would result in a greater decline in the CFdi when pressure-time product (PTPdi) was kept constant. Five healthy subjects performed periods of intermittent quasi-static diaphragmatic contractions with a fixed duty cycle. In separate runs, subjects targeted transdiaphragmatic pressures (Pdi) by performing end-inspiratory holds with the glottis open and expulsive maneuvers at end-expiratory lung volume (EELV). Diaphragm activation and pressures were measured with an electrode array and balloons mounted on an esophago-gastric catheter, respectively. The EAdi, which was 25+/-8%(S.D.) of maximum at EELV, increased to 61+/-8% (P<0.001) when an identical Pdi (averaging 31+/-13 cmH2O) was generated at a higher lung volume (77% of inspiratory capacity). The latter was associated with a 17% greater decline in CFdi (P=0.012). In order to reproduce at EELV, the decrease in CFdi observed at the increased lung volume, a two-fold increase in PTPdi was required. We conclude that CFdi responds specifically to increased diaphragm activation when pressure-time product remains constant.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.resp.2004.11.006DOI Listing

Publication Analysis

Top Keywords

diaphragm activation
16
increased diaphragm
8
center frequency
8
duty cycle
8
increased
5
activation
4
diaphragm
4
activation diaphragm
4
diaphragm power
4
power spectrum
4

Similar Publications

Chilaiditi Sign and Syndrome as a Finding in the Emergency Room: A Case Report.

Cureus

December 2024

Clinical Pathology Department, Unidade Local de Saúde do Nordeste, Unidade Hospitalar de Bragança, Bragança, PRT.

The Chilaiditi sign is the presence of a loop of bowel interposed between the liver and the diaphragm. In most cases, the Chilaiditi sign is diagnosed as a rare incidental radiological finding on chest X-rays or the abdomen of asymptomatic patients. When associated with symptoms, it is named Chilaiditi syndrome.

View Article and Find Full Text PDF

Electrocatalytic methane conversion via in-situ generated superoxide radicals in an aprotic ionic liquid.

J Colloid Interface Sci

January 2025

Institute of Applied Electrochemistry, College of Chemistry, Beijing University of Chemical Technology, Beijing 100029 PR China. Electronic address:

The electrochemical activation and partial oxidation of methane are highly attractive to enable the direct conversion in a sustainable and decentralized way. Herein, we report an electrochemical system in a non-diaphragm electrochemical bath to convert CH to CHOH and CHCHOH at room temperature, in which VO·HO as the anodic catalyst to activate CH and an aprotic ionic liquid [BMIM]BF as supporting electrolyte to control superoxide radicals (O) as the main active oxygen species generated on cathode. As a result, methanol and ethanol were identified as the liquid products, and the superior methanol Faraday efficiency (FE) of 32.

View Article and Find Full Text PDF

Implantable Passive Sensors for Biomedical Applications.

Sensors (Basel)

December 2024

School of Electrical and Computer Engineering, National Technical University of Athens, 15772 Athens, Greece.

Article Synopsis
  • Implantable sensors are becoming popular for localized and continuous monitoring in medical settings, allowing for early detection and timely interventions.
  • There are two main types of implantable sensors: active, which have more advanced functionalities but require a power source, and passive, which don't need power and offer simpler, smaller designs.
  • This review focuses on passive sensor technologies, discussing their materials, detection methods, clinical applications, advantages over active sensors, and important considerations for their packaging and compatibility with the human body.
View Article and Find Full Text PDF

Background: Respiratory muscle weakness in heart failure (HF) can deteriorate its symptoms such as fatigue, dyspnea, and impaired functional status. Pulmonary rehabilitation can strengthen these muscles. This study aimed to determine the impact of breathing exercises on fatigue severity, dyspnea, and functional classification in HF patients.

View Article and Find Full Text PDF

Development and characterization of starch/polyvinyl alcohol active films with slow-release property by utilizing Mucorracemosus Fresenius mycelium to load with clove essential oil.

Int J Biol Macromol

January 2025

College of Food Science and Technology, Shanghai Ocean University, Shanghai 201306, China; Shanghai Engineering Research Center of Aquatic-Product Processing & Preservation, Shanghai 201306, China; Laboratory of Quality and Safety Risk Assessment for Aquatic Products on Storage and Preservation (Shanghai), Ministry of Agriculture, Shanghai 201306, China. Electronic address:

The controlled release active packaging film represents a novel technology that always can effectively slow down the release of active agents, extending their efficacy. Mucorracemosus Fresenius (MF) mycelium was prepared and used as an adsorption carrier to load clove essential oil (CEO). The CEO/MF complexes were incorporated into the starch/polyvinyl alcohol (Starch/PVA) matrix to develop active films.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!